Electrostatic Hazard in Processing Industry Awareness Training
DEVELOP Training Center menyelenggarakan Kelas Electrostatic Hazard in Processing Industry Awareness Training yang akan mengajarkan kepada Anda tentang :
- Aplikasi teknik-teknik terkait Electrical&Instrument Inspection untuk Hazardous Area&Classification
- Penilaian/Assessment sistem instalasi peralatan untuk daerah bahaya
- Pemeliharaan Peralatan untuk daerah bahaya menggunakan tools dan prosedur secara tepat
- Metoda analisa dan klasifikasi atmosfer gas eksplosif
- Pemilihan dan instalasi peralatan secara benar agar aman digunakan
Pembahasan materi mengetengahkan contoh-contoh latihan dalam konteks dunia proyek sehingga lebih familier dengan aktivitas proyek sehari-hari.

Electrostatic Hazard in Processing Industry Awareness Training
DEVELOP menerapkan Syllabus Electrostatic Hazard in Processing Industry Awareness Training dengan tahap-tahap pembelajaran berkualitas sbb :
Sesi 1-2
Skill Focus:
- Electrostatic Hazard in Processing Industry Overview
- Applicable Related Standards&Codes (NFPA,IEC,ISA,EN)
- Hazardous Locations & Hazardous Explosive Materials
- Oil Gas, Power Plant, Petrochemical, Process Plant, Mining/Dust&Manufacturing Industries
- Area Classification
- Explosive Gas Atmospheres
- Group Gas&Class temperature
- Flammable Vapors&Explosive/Ignitable Mixture
- Flammable Material Present Continuously, Intermittently&Present Abnormally
- Zone 0,Zone 1&Zone 2
- Zone 20,Zone 21&Zone22
- IEC Classification per IEC-60079-17
- Ansi/Nfpa 70 National Electric Code
- Flash Point, Flammable Liquid &Nfpa 30 Test Procedures
- Combustible Liquid
- Class I Areas/Locations&Class I Temperature
- Class I Division 1 & Division 2
- Abnormal Operation (Failure of Processing Equipment&Failure of ventilation)
- Explosive Range of Class I Flammables
- Flammable vapors in Equipments Usage
- Pump Seals
- Valve Packing
- Overpressure Protection Devices (Relief Valves, Rupture Discs, Conservation Vents)
- Compressor Seals
- Process Drains&Vents
- Adequate Ventilation & Safe Gap (Mesg)
- Minimum Igniting Current (Mic) Ratio
- Authority Jurisdiction
- Unclassified areas
- Determination Of Area Classification
- Assessment Method (Process Safety Engineer, Operations-Mechanical Integrity Engineer,Design Engineer, Risk Assessment)
- Area Classification Flowchart Class I
- Area Classification Procedure (Plot Plans, Process Flow Diagrams, P&Id, Pfd)
- Process Pressure, Temperature&Flow Rates
- Stream Material Balance
- Electrostatic Hazard in Processing Industry Case Studies
Sesi 3-4
Skill Focus:
- Risk Assessment Methodology
- Determine Fire Hazard Properties of Combustible Materials
- Classified Area Extent in Equipments (Vessels, Tanks, Trenches, Sumps, Building Structures, Dikes, Partitions, Levees& Other Items affect Dispersion Process Material&Wind Direction)
- Point Sources of Emissions & Area Classification Documentation
- Equipment in Classified Areas
- Protection Techniques Divisions
- Equipment Approval Equipment
- Equipment In Class I Locations
- Equipment In Class Ii Locations
- Certification Bodies
- Product Utilization
- Flameproof (Special Motor enclosures)
- Increased Safety which Involves More Robust Electrical Designs
- Div 1 Design Considerations
- Maximum Explosive Pressure, Safe Clearance (Flame path)&Minimum Ignition Temperature
- Special Insulation Or Thermostats
- NEC Temperature Codes
- Motor Protection Methods
- Intrinsically Safe (2 Faults)
- Flameproof
- Tighter Constraint son Electrical Design
- Purged
- Non Sparking
- Increased Safety Terminal Box
- Motor Nameplate Ul Listed Nameplate
- Methods Of Protection & Hazard Reduction
- Confine The Explosion
- Energy Limiting
- Purging And Pressurization
- Oil Immersion
- Physical Isolation
- Nonincendive System
- Electrostatic Hazard in Processing Industry Case Studies

Electrostatic Hazard in Processing Industry Awareness Training
Materi Training dirancang khusus oleh para praktisi Project Engineers sesuai dengan experience dan solid knowledge mereka dalam menangani project. Anda akan mendapat sharing ilmu langsung dari para praktisi yang berpengalaman bertahun-tahun.
Selama training, instruktur kami akan menggunakan kombinasi teori serta praktek langsung dengan studi kasus telah dipersiapkan yang menyerupai Proyek nyata.
QUICK REGISTER :
Tags: Abnormal Operation Failure of Processing Equipment-Failure of ventilation, Adequate Ventilation-Safe Gap MESG, ANSI-NFPA 70 National Electric Code, Applicable Related Standards-Codes NFPA-IEC-ISA-EN, Area Classification, Area Classification Flowchart Class I, Area Classification Procedure Plot Plans-Process Flow Diagrams-P-ID-PFD, Assessment Method Process Safety Engineer-Operations-, Authority Jurisdiction, Certification Bodies, Class I Areas-Locations-Class I Temperature, Class I Division 1-Division 2, Classified Area Extent in Equipments Vessels-Tanks-Trenches, Combustible Liquid, Compressor Seals, Confine The Explosion, Design Engineer-Risk Assessment, Determination Of Area Classification, Determine Fire Hazard Properties of Combustible Materials, Div 1 Design Considerations, Electrostatic Hazard in Processing Industry Case Studies, Electrostatic Hazard in Processing Industry Overview, Energy Limiting, Equipment Approval Equipment, Equipment In Class I Locations, Equipment In Class Ii Locations, Equipment in Classified Areas, Explosive Gas Atmospheres, Explosive Range of Class I Flammables, Flameproof, Flameproof Special Motor enclosures, Flammable Material Present Continuously-Intermittently-Present Abnormally, Flammable vapors in Equipments Usage, Flammable Vapors-Explosive-Ignitable Mixture, Flash Point-Flammable Liquid-NFPA 30 Test Procedures, Group Gas-Class temperature, Hazardous Locations-Hazardous Explosive Materials, IEC Classification per IEC-60079-17, Increased Safety Terminal Box, Increased Safety which Involves More Robust Electrical Designs, Intrinsically Safe 2 Faults, Items affect Dispersion Process Material-Wind Direction, jadwal training jakarta Electrostatic Hazard in Processing Industry, kursus privat Electrostatic Hazard in Processing Industry, Kursus Seminar Webinar Bimtek Pelatihan Electrostatic Hazard in Processing Industry, Manufacturing Industries, Manufacturing Industries Hazards, Maximum Explosive Pressure-, Mechanical Integrity Engineer-, Methods Of Protection-Hazard Reduction, Minimum Igniting Current MIC Ratio, Minimum Ignition Temperature, Mining-Dust Hazards, Motor Nameplate Ul Listed Nameplate, Motor Protection Methods, NEC Temperature Codes, Non Sparking, Nonincendive System, Oil Gas Hazards, Oil Gas-Power Plant-Petrochemical-Process Plant-Mining-Dust-, Oil Immersion, Overpressure Protection Devices Relief Valves-Rupture Discs-Conservation Vents, Petrochemical Hazards, Physical Isolation, Point Sources of Emissions-Area Classification Documentation, Power Plant Hazards, Process Drains-Vents, Process Plant Hazards, Process Pressure-Temperature-Flow Rates, Product Utilization, Protection Techniques Divisions, Pump Seals, Purged, Purging And Pressurization, Pusat Pelatihan Electrostatic Hazard in Processing Industry, Risk Assessment Methodology, Safe Clearance Flame path, Special Insulation Or Thermostats, Stream Material Balance, Tighter Constraint son Electrical Design, Training Analis Proses Electrostatic Hazard, Training Commissioning Engineer Electrostatic Hazard, Training Commissioning Manager Electrostatic Hazard, Training Construction Manager Electrostatic Hazard, Training Construction-Fabrication Manager Electrostatic Hazard, Training Electrostatic Hazard in Processing Industry, Training Engineering Manager Electrostatic Hazard, Training Fab.-Installion SI Electrostatic Hazard, Training HSE Coordinator Electrostatic Hazard, Training HSE Manager Electrostatic Hazard, Training HSE Officer Electrostatic Hazard, Training HSE Onshore Fabrication Coordinator Electrostatic Hazard, Training Installation Manager Electrostatic Hazard, Training Interface Manager Electrostatic Hazard, Training Kontraktor Electrostatic Hazard, Training Operations Assurance Manager Electrostatic Hazard, Training Ops. Assurance Manager Electrostatic Hazard, Training Procurement Manager Electrostatic Hazard, Training Project Control Manager Electrostatic Hazard, Training Project Control- Services Manager Electrostatic Hazard, Training Project Coordinator Electrostatic Hazard, Training Project Engineer Electrostatic Hazard, Training Project Manager Electrostatic Hazard, Training Project Owner-Client Electrostatic Hazard, Training QA-QC Manager Electrostatic Hazard, Training QA-QC Pengawas-QC pemeriksa kualitas Electrostatic Hazard, Training QC Inspector Electrostatic Hazard, Training Site Engineer Electrostatic Hazard, Training Site Planner Electrostatic Hazard, Training Supervisor-Superintendent Electrostatic Hazard, Training Supervisors Electrostatic Hazard, Unclassified areas, Valve Packing, Zone 0-Zone 1-Zone 2, Zone 20-Zone 21-Zone22