Comments Off on Electrical Hazardous Areas Installation Inspection&Maintenance IEC 60079-17 Training
DEVELOP Training Center menyelenggarakan Kelas Electrical Hazardous Areas Installation InspectionMaintenance IEC 60079-17 Training yang akan mengajarkan kepada Anda tentang :
Inspeksi KelistrikanInstrumentasi/ElectricalInstrument Inspection Hazardous Area sesuai dengan Standar Internasional
Aplikasi teknik-teknik terkait Electrical/Instrument Inspection untuk Hazardous Area
Inspeksi efektif untuk sistem Kelistrikan/Instrumentasi dengan Studi Kasus real plant operation dari praktisi
Penilaian/Assessment sistem instalasi peralatan untuk daerah bahaya
Metode analisa dan klasifikasi atmosfer gas eksplosif
Pemilihan dan instalasi peralatan secara benar agar aman digunakan
Pembahasan materi mengetengahkan contoh-contoh latihan dalam konteks dunia proyek sehingga lebih familier dengan aktivitas proyek sehari-hari.
Electrical Hazardous Areas Installation Inspection&Maintenance IEC 60079-17 Training
DEVELOP menerapkan Syllabus Electrical Hazardous Areas Installation InspectionMaintenance IEC 60079-17 Training dengan tahap-tahap pembelajaran berkualitas sbb :
Sesi 1-2
Skill Focus:
Electrical Hazardous Areas Installation InspectionMaintenance IEC 60079-17 Overview
Applicable Related StandardsCodes (NFPA,IEC,ISA,EN)
Hazardous Locations Hazardous Explosive Materials
Oil Gas, Power Plant, Petrochemical, Process Plant, Mining/DustManufacturing Industries
Area Classification
Explosive Gas Atmospheres
Group GasClass temperature
Flammable VaporsExplosive/Ignitable Mixture
Flammable Material Present Continuously, IntermittentlyPresent Abnormally
Zone 0,Zone 1Zone 2
Zone 20,Zone 21Zone22
IEC Classification per IEC-60079-17
Ansi/Nfpa 70 National Electric Code
Flash Point, Flammable Liquid Nfpa 30 Test Procedures
Combustible Liquid
Class I Areas/LocationsClass I Temperature
Class I Division 1 Division 2
Abnormal Operation (Failure of Processing EquipmentFailure of ventilation)
Area Classification Procedure (Plot Plans, Process Flow Diagrams, PId, Pfd)
Process Pressure, TemperatureFlow Rates
Stream Material Balance
Electrical Hazardous Areas IEC 60079-17 Case Studies
Sesi 3-4
Skill Focus:
Risk Assessment Methodology
Determine Fire Hazard Properties of Combustible Materials
Classified Area Extent in Equipments (Vessels, Tanks, Trenches, Sumps, Building Structures, Dikes, Partitions, Levees Other Items affect Dispersion Process MaterialWind Direction)
Point Sources of Emissions Area Classification Documentation
Equipment in Classified Areas
Protection Techniques Divisions
Equipment Approval Equipment
Equipment In Class I Locations
Equipment In Class Ii Locations
Certification Bodies
Product Utilization
Flameproof (Special Motor enclosures)
Increased Safety which Involves More Robust Electrical Designs
Div 1 Design Considerations
Maximum Explosive Pressure, Safe Clearance (Flame path)Minimum Ignition Temperature
Special Insulation Or Thermostats
NEC Temperature Codes
Motor Protection Methods
Intrinsically Safe (2 Faults)
Flameproof
Tighter Constraint son Electrical Design
Purged
Non Sparking
Increased Safety Terminal Box
Motor Nameplate Ul Listed Nameplate
Methods Of Protection Hazard Reduction
Confine The Explosion
Energy Limiting
Purging And Pressurization
Oil Immersion
Physical Isolation
Nonincendive System
Electrical Hazardous Areas IEC 60079-17 Case Studies
Electrical Hazardous Areas Installation Inspection&Maintenance IEC 60079-17 Training
Selama training, instruktur kami akan menggunakan kombinasi teori serta praktek langsung dengan studi kasus telah dipersiapkan yang menyerupai Proyek nyata.
Materi Training dirancang khusus oleh para praktisi Project Engineers sesuai dengan experience dan solid knowledge mereka dalam menangani project. Anda akan mendapat sharing ilmu langsung dari para praktisi yang berpengalaman bertahun-tahun.
QUICK REGISTER :
Keterampilan Penting lainnya untuk Pengembangan Profesi Anda: