{"id":9487,"date":"2021-11-01T17:40:59","date_gmt":"2021-11-01T17:40:59","guid":{"rendered":"https:\/\/develop.co.id\/training\/generator-underfrequency-protection-coordination-training\/"},"modified":"2026-08-20T06:49:01","modified_gmt":"2026-08-20T06:49:01","slug":"generator-underfrequency-protection-coordination-training","status":"publish","type":"post","link":"https:\/\/develop.co.id\/training\/generator-underfrequency-protection-coordination-training\/","title":{"rendered":"Generator Underfrequency Protection Coordination Training"},"content":{"rendered":"<p>DEVELOP Training Center menyelenggarakan Kelas Generator Underfrequency Protection Coordination yang sangat berguna untuk mendapatkan pengetahuan tentang koordinasi proteksi underfrequency generator, pemilihan ambang frekuensi dan delay, serta pengaturan respons generator saat frekuensi sistem menurun. <br \/><\/br> Pelatihan dilaksanakan melalui pemaparan materi dan diskusi interaktif di dalam kelas. Peserta pelatihan didorong untuk berperan aktif dalam memahami materi yang disampaikan oleh instruktur. <br \/><\/br> <center> <img fetchpriority=\"high\" decoding=\"async\" src=\"https:\/\/develop.co.id\/wp-content\/uploads\/2025\/09\/DV-GEN-026.jpg\" alt=\"Generator Underfrequency Protection Coordination\" width=\"500\" height=\"500\"><figcaption> Generator Underfrequency Protection Coordination <\/figcaption><\/center> <br \/><\/br> DEVELOP mengimplementasikan Syllabus Kelas Generator Underfrequency Protection Coordination dengan tahap pembelajaran berkualitas sebagai berikut:<\/p>\n<blockquote><p><b>Sesi 1-2<\/b><\/p>\n<ul>\n<li>Generator frequency characteristics and operating limits<\/li>\n<li>Causes of system underfrequency conditions<\/li>\n<li>Underfrequency protection zones<\/li>\n<li>Frequency relay operating characteristics<\/li>\n<li>Pickup frequency selection<\/li>\n<li>Time-delay characteristics for underfrequency elements<\/li>\n<li>Generator load response during frequency decline<\/li>\n<li>Coordination with load-shedding functions<\/li>\n<li>Generator turbine and prime mover response<\/li>\n<li>Coordination between generating units<\/li>\n<li>Frequency measurement and relay filtering<\/li>\n<li>Case Study<\/li>\n<\/ul>\n<p><b>Sesi 3-4<\/b><\/p>\n<ul>\n<li>Underfrequency relay setting coordination<\/li>\n<li>Frequency threshold selection<\/li>\n<li>Time-delay grading between protection stages<\/li>\n<li>Rate-of-change frequency interaction<\/li>\n<li>Generator operating condition effects<\/li>\n<li>Load-shedding coordination<\/li>\n<li>Interconnected generator frequency response<\/li>\n<li>Backup frequency protection<\/li>\n<li>Review of underfrequency trip sequences<\/li>\n<li>Identification of setting conflicts<\/li>\n<li>Preparation of generator frequency settings<\/li>\n<li>Validation of coordinated frequency protection<\/li>\n<li>Case Study<\/li>\n<\/ul>\n<\/blockquote>\n<p><\/br> Sejalan dengan teori yang disampaikan, sebanyak mungkin akan disertakan contoh-contoh studi kasus yang relevan dengan kondisi industri saat ini. Peserta juga diberikan kesempatan untuk mengajukan pertanyaan dan mendiskusikan topik-topik yang dibahas. <br \/><\/br> <center> <img decoding=\"async\" src=\"https:\/\/develop.co.id\/wp-content\/uploads\/2025\/09\/DV-TESTIMONIAL-009.jpg\" alt=\"Generator Underfrequency Protection Coordination\" width=\"500\" height=\"500\"><figcaption> Generator Underfrequency Protection Coordination <\/figcaption><\/center> <br \/><\/br> Materi Training dirancang khusus oleh para praktisi dan tenaga ahli yang kompeten serta telah berpengalaman sesuai dengan experience dan solid knowledge  mereka. Anda akan mendapat sharing ilmu langsung dari para praktisi yang berpengalaman bertahun-tahun. <br \/><\/br> Selama training, instruktur kami akan menggunakan kombinasi teori serta praktek langsung dengan studi kasus telah dipersiapkan yang menyerupai Proyek nyata. <br \/><\/br> \n<div class=\"wpcf7 no-js\" id=\"wpcf7-f4427-o1\" lang=\"en-US\" dir=\"ltr\" data-wpcf7-id=\"4427\">\n<div class=\"screen-reader-response\"><p role=\"status\" aria-live=\"polite\" aria-atomic=\"true\"><\/p> <ul><\/ul><\/div>\n<form action=\"\/training\/wp-json\/wp\/v2\/posts\/9487#wpcf7-f4427-o1\" method=\"post\" class=\"wpcf7-form init\" aria-label=\"Contact form\" novalidate=\"novalidate\" data-status=\"init\">\n<fieldset class=\"hidden-fields-container\"><input type=\"hidden\" name=\"_wpcf7\" value=\"4427\" \/><input type=\"hidden\" name=\"_wpcf7_version\" value=\"6.2.5\" \/><input type=\"hidden\" name=\"_wpcf7_locale\" value=\"en_US\" \/><input type=\"hidden\" name=\"_wpcf7_unit_tag\" value=\"wpcf7-f4427-o1\" \/><input type=\"hidden\" name=\"_wpcf7_container_post\" value=\"0\" \/><input type=\"hidden\" name=\"_wpcf7_posted_data_hash\" value=\"\" \/>\n<\/fieldset>\n<blockquote>\n\t<p><b>QUICK REGISTRATION &#10004;<\/b>\n\t<\/p>\n<\/blockquote>\n<div class=\"c-input-group\">\n\t<p><span class=\"wpcf7-form-control-wrap\" data-name=\"your-name\"><input size=\"40\" maxlength=\"400\" class=\"wpcf7-form-control wpcf7-text wpcf7-validates-as-required\" aria-required=\"true\" aria-invalid=\"false\" placeholder=\"Full name\" value=\"\" type=\"text\" name=\"your-name\" \/><\/span><br \/>\n<span class=\"wpcf7-form-control-wrap\" data-name=\"your-email\"><input size=\"40\" maxlength=\"400\" class=\"wpcf7-form-control wpcf7-email wpcf7-validates-as-required wpcf7-text wpcf7-validates-as-email\" aria-required=\"true\" aria-invalid=\"false\" placeholder=\"Email\" value=\"\" type=\"email\" name=\"your-email\" \/><\/span><br \/>\n<span class=\"wpcf7-form-control-wrap\" data-name=\"tel-428\"><input size=\"40\" maxlength=\"400\" class=\"wpcf7-form-control wpcf7-tel wpcf7-validates-as-required wpcf7-text wpcf7-validates-as-tel\" aria-required=\"true\" aria-invalid=\"false\" placeholder=\"Phone\" value=\"\" type=\"tel\" name=\"tel-428\" \/><\/span>\n\t<\/p>\n\t<p><span class=\"wpcf7-form-control-wrap\" data-name=\"your-message\"><textarea cols=\"10\" rows=\"10\" maxlength=\"2000\" class=\"wpcf7-form-control wpcf7-textarea\" aria-invalid=\"false\" placeholder=\"Special message\" name=\"your-message\"><\/textarea><\/span>\n\t<\/p>\n\t<p><span id=\"wpcf7-6b0119ba9cfee-wrapper\" class=\"wpcf7-form-control-wrap cf7apps-honeypot-wrap honeypot-469-wrap\" data-cf7apps-honeypot=\"honeypot-469\" style=\"position:absolute;width:1px;height:1px;padding:0;margin:-1px;overflow:hidden;clip:rect(0,0,0,0);white-space:nowrap;border:0;\"><input type=\"hidden\" name=\"honeypot-469-random-hash\" value=\"20261121\"><input type=\"hidden\" name=\"honeypot-469-time-token\" value=\"MTc5NTIzNDIzNA==.c29b2c33322036d6e8655943282f85bca0ff7510395e9018deffee0a39c29946\"><label\n\t\t    for=\"wpcf7-6b0119ba9cfee-field\"\n\t\t    class=\"hp-message\"\n        >Please leave this field empty.<\/label><input\n\t    id=\"wpcf7-6b0119ba9cfee-field\"\n\t    \n\t    class=\"wpcf7-form-control wpcf7-text\"\n\t    type=\"text\"\n\t    name=\"ghyw3azccfl5\"\n\t    value=\"\"\n\t    autocomplete=\"new-password\"\n\t    tabindex=\"1000\"\n\t    data-cf7apps-tabindex=\"1000\"\n    \/><\/span><br \/>\n<input class=\"wpcf7-form-control wpcf7-submit has-spinner\" type=\"submit\" value=\"REGISTER NOW\" \/>\n\t<\/p>\n<\/div><div class=\"wpcf7-response-output\" aria-hidden=\"true\"><\/div>\n<\/form>\n<\/div>\n<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Pelajari koordinasi proteksi underfrequency generator untuk mengatur ambang frekuensi, menyelaraskan delay relay, dan menjaga kestabilan sistem pembangkitan.<\/p>\n","protected":false},"author":1,"featured_media":10043,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_monsterinsights_skip_tracking":false,"footnotes":""},"categories":[34,38],"tags":[193],"class_list":["post-9487","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-electrical-engineering","category-instrument-engineering","tag-electrical-engineering"],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 5.0.5.1 - aioseo.com -->\n\t<meta name=\"description\" content=\"Pelajari koordinasi proteksi underfrequency generator untuk mengatur ambang frekuensi, menyelaraskan delay relay, dan menjaga kestabilan sistem pembangkitan.\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<link rel=\"canonical\" href=\"https:\/\/develop.co.id\/training\/generator-underfrequency-protection-coordination-training\/\" \/>\n\t\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 5.0.5.1\" \/>\n\t\t<meta property=\"og:locale\" content=\"en_US\" \/>\n\t\t<meta property=\"og:site_name\" content=\"DEVELOP - Oil Gas,Petrochemical, Power Plant,Mining&amp;Industrial Training Specialist\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"Generator Underfrequency Protection Coordination Training - DEVELOP\" \/>\n\t\t<meta property=\"og:description\" content=\"Pelajari koordinasi proteksi underfrequency generator untuk mengatur ambang frekuensi, menyelaraskan delay relay, dan menjaga kestabilan sistem pembangkitan.\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/develop.co.id\/training\/generator-underfrequency-protection-coordination-training\/\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/develop.co.id\/training\/wp-content\/uploads\/2026\/07\/DEVELOP-Logo-ls4-300x150-1.png\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/develop.co.id\/training\/wp-content\/uploads\/2026\/07\/DEVELOP-Logo-ls4-300x150-1.png\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2021-11-01T17:40:59+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2026-08-20T06:49:01+00:00\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:title\" content=\"Generator Underfrequency Protection Coordination Training - DEVELOP\" \/>\n\t\t<meta name=\"twitter:description\" content=\"Pelajari koordinasi proteksi underfrequency generator untuk mengatur ambang frekuensi, menyelaraskan delay relay, dan menjaga kestabilan sistem pembangkitan.\" \/>\n\t\t<meta name=\"twitter:image\" content=\"https:\/\/develop.co.id\/training\/wp-content\/uploads\/2026\/07\/DEVELOP-Logo-ls4-300x150-1.png\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"BlogPosting\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/generator-underfrequency-protection-coordination-training\\\/#blogposting\",\"name\":\"Generator Underfrequency Protection Coordination Training - DEVELOP\",\"headline\":\"Generator Underfrequency Protection Coordination Training\",\"author\":{\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/author\\\/developtraining\\\/#author\"},\"publisher\":{\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/#organization\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/develop.co.id\\\/training\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/generator-underfrequency-protection-coordination-training_9487_74ac1.png\",\"width\":800,\"height\":600},\"datePublished\":\"2021-11-01T17:40:59+00:00\",\"dateModified\":\"2026-08-20T06:49:01+00:00\",\"inLanguage\":\"en-US\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/generator-underfrequency-protection-coordination-training\\\/#webpage\"},\"isPartOf\":{\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/generator-underfrequency-protection-coordination-training\\\/#webpage\"},\"articleSection\":\"Electrical Engineering, Instrument Engineering, Electrical Engineering\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/generator-underfrequency-protection-coordination-training\\\/#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/#listItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/develop.co.id\\\/training\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/category\\\/engineering-technical\\\/#listItem\",\"name\":\"Engineering &amp; Technical\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/category\\\/engineering-technical\\\/#listItem\",\"position\":2,\"name\":\"Engineering &amp; Technical\",\"item\":\"https:\\\/\\\/develop.co.id\\\/training\\\/category\\\/engineering-technical\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/category\\\/engineering-technical\\\/electrical-engineering\\\/#listItem\",\"name\":\"Electrical Engineering\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/#listItem\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/category\\\/engineering-technical\\\/electrical-engineering\\\/#listItem\",\"position\":3,\"name\":\"Electrical Engineering\",\"item\":\"https:\\\/\\\/develop.co.id\\\/training\\\/category\\\/engineering-technical\\\/electrical-engineering\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/generator-underfrequency-protection-coordination-training\\\/#listItem\",\"name\":\"Generator Underfrequency Protection Coordination Training\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/category\\\/engineering-technical\\\/#listItem\",\"name\":\"Engineering &amp; Technical\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/generator-underfrequency-protection-coordination-training\\\/#listItem\",\"position\":4,\"name\":\"Generator Underfrequency Protection Coordination Training\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/category\\\/engineering-technical\\\/electrical-engineering\\\/#listItem\",\"name\":\"Electrical Engineering\"}}]},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/#organization\",\"name\":\"DEVELOP\",\"description\":\"Oil Gas,Petrochemical, Power Plant,Mining&Industrial Training Specialist\",\"url\":\"https:\\\/\\\/develop.co.id\\\/training\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/develop.co.id\\\/training\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/DEVELOP-Logo-ls4-300x150-1.png\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/generator-underfrequency-protection-coordination-training\\\/#organizationLogo\",\"width\":300,\"height\":150},\"image\":{\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/generator-underfrequency-protection-coordination-training\\\/#organizationLogo\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/author\\\/developtraining\\\/#author\",\"url\":\"https:\\\/\\\/develop.co.id\\\/training\\\/author\\\/developtraining\\\/\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/generator-underfrequency-protection-coordination-training\\\/#authorImage\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/6b88ccabac9c627e76fb131519cdc3ef0e725eb1ff178c0eaa169a92fc8becc5?s=96&d=mm&r=g\",\"width\":96,\"height\":96}},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/generator-underfrequency-protection-coordination-training\\\/#webpage\",\"url\":\"https:\\\/\\\/develop.co.id\\\/training\\\/generator-underfrequency-protection-coordination-training\\\/\",\"name\":\"Generator Underfrequency Protection Coordination Training - DEVELOP\",\"description\":\"Pelajari koordinasi proteksi underfrequency generator untuk mengatur ambang frekuensi, menyelaraskan delay relay, dan menjaga kestabilan sistem pembangkitan.\",\"inLanguage\":\"en-US\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/generator-underfrequency-protection-coordination-training\\\/#breadcrumblist\"},\"author\":{\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/author\\\/developtraining\\\/#author\"},\"creator\":{\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/author\\\/developtraining\\\/#author\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/develop.co.id\\\/training\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/generator-underfrequency-protection-coordination-training_9487_74ac1.png\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/generator-underfrequency-protection-coordination-training\\\/#mainImage\",\"width\":800,\"height\":600},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/generator-underfrequency-protection-coordination-training\\\/#mainImage\"},\"datePublished\":\"2021-11-01T17:40:59+00:00\",\"dateModified\":\"2026-08-20T06:49:01+00:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/#website\",\"url\":\"https:\\\/\\\/develop.co.id\\\/training\\\/\",\"name\":\"DEVELOP\",\"description\":\"Oil Gas,Petrochemical, Power Plant,Mining&Industrial Training Specialist\",\"inLanguage\":\"en-US\",\"publisher\":{\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/#organization\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"Generator Underfrequency Protection Coordination Training - DEVELOP","description":"Pelajari koordinasi proteksi underfrequency generator untuk mengatur ambang frekuensi, menyelaraskan delay relay, dan menjaga kestabilan sistem pembangkitan.","canonical_url":"https:\/\/develop.co.id\/training\/generator-underfrequency-protection-coordination-training\/","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"BlogPosting","@id":"https:\/\/develop.co.id\/training\/generator-underfrequency-protection-coordination-training\/#blogposting","name":"Generator Underfrequency Protection Coordination Training - DEVELOP","headline":"Generator Underfrequency Protection Coordination Training","author":{"@id":"https:\/\/develop.co.id\/training\/author\/developtraining\/#author"},"publisher":{"@id":"https:\/\/develop.co.id\/training\/#organization"},"image":{"@type":"ImageObject","url":"https:\/\/develop.co.id\/training\/wp-content\/uploads\/2026\/08\/generator-underfrequency-protection-coordination-training_9487_74ac1.png","width":800,"height":600},"datePublished":"2021-11-01T17:40:59+00:00","dateModified":"2026-08-20T06:49:01+00:00","inLanguage":"en-US","mainEntityOfPage":{"@id":"https:\/\/develop.co.id\/training\/generator-underfrequency-protection-coordination-training\/#webpage"},"isPartOf":{"@id":"https:\/\/develop.co.id\/training\/generator-underfrequency-protection-coordination-training\/#webpage"},"articleSection":"Electrical Engineering, Instrument Engineering, Electrical Engineering"},{"@type":"BreadcrumbList","@id":"https:\/\/develop.co.id\/training\/generator-underfrequency-protection-coordination-training\/#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/develop.co.id\/training\/#listItem","position":1,"name":"Home","item":"https:\/\/develop.co.id\/training\/","nextItem":{"@type":"ListItem","@id":"https:\/\/develop.co.id\/training\/category\/engineering-technical\/#listItem","name":"Engineering &amp; Technical"}},{"@type":"ListItem","@id":"https:\/\/develop.co.id\/training\/category\/engineering-technical\/#listItem","position":2,"name":"Engineering &amp; Technical","item":"https:\/\/develop.co.id\/training\/category\/engineering-technical\/","nextItem":{"@type":"ListItem","@id":"https:\/\/develop.co.id\/training\/category\/engineering-technical\/electrical-engineering\/#listItem","name":"Electrical Engineering"},"previousItem":{"@type":"ListItem","@id":"https:\/\/develop.co.id\/training\/#listItem","name":"Home"}},{"@type":"ListItem","@id":"https:\/\/develop.co.id\/training\/category\/engineering-technical\/electrical-engineering\/#listItem","position":3,"name":"Electrical Engineering","item":"https:\/\/develop.co.id\/training\/category\/engineering-technical\/electrical-engineering\/","nextItem":{"@type":"ListItem","@id":"https:\/\/develop.co.id\/training\/generator-underfrequency-protection-coordination-training\/#listItem","name":"Generator Underfrequency Protection Coordination Training"},"previousItem":{"@type":"ListItem","@id":"https:\/\/develop.co.id\/training\/category\/engineering-technical\/#listItem","name":"Engineering &amp; Technical"}},{"@type":"ListItem","@id":"https:\/\/develop.co.id\/training\/generator-underfrequency-protection-coordination-training\/#listItem","position":4,"name":"Generator Underfrequency Protection Coordination Training","previousItem":{"@type":"ListItem","@id":"https:\/\/develop.co.id\/training\/category\/engineering-technical\/electrical-engineering\/#listItem","name":"Electrical Engineering"}}]},{"@type":"Organization","@id":"https:\/\/develop.co.id\/training\/#organization","name":"DEVELOP","description":"Oil Gas,Petrochemical, Power Plant,Mining&Industrial Training Specialist","url":"https:\/\/develop.co.id\/training\/","logo":{"@type":"ImageObject","url":"https:\/\/develop.co.id\/training\/wp-content\/uploads\/2026\/07\/DEVELOP-Logo-ls4-300x150-1.png","@id":"https:\/\/develop.co.id\/training\/generator-underfrequency-protection-coordination-training\/#organizationLogo","width":300,"height":150},"image":{"@id":"https:\/\/develop.co.id\/training\/generator-underfrequency-protection-coordination-training\/#organizationLogo"}},{"@type":"Person","@id":"https:\/\/develop.co.id\/training\/author\/developtraining\/#author","url":"https:\/\/develop.co.id\/training\/author\/developtraining\/","image":{"@type":"ImageObject","@id":"https:\/\/develop.co.id\/training\/generator-underfrequency-protection-coordination-training\/#authorImage","url":"https:\/\/secure.gravatar.com\/avatar\/6b88ccabac9c627e76fb131519cdc3ef0e725eb1ff178c0eaa169a92fc8becc5?s=96&d=mm&r=g","width":96,"height":96}},{"@type":"WebPage","@id":"https:\/\/develop.co.id\/training\/generator-underfrequency-protection-coordination-training\/#webpage","url":"https:\/\/develop.co.id\/training\/generator-underfrequency-protection-coordination-training\/","name":"Generator Underfrequency Protection Coordination Training - DEVELOP","description":"Pelajari koordinasi proteksi underfrequency generator untuk mengatur ambang frekuensi, menyelaraskan delay relay, dan menjaga kestabilan sistem pembangkitan.","inLanguage":"en-US","isPartOf":{"@id":"https:\/\/develop.co.id\/training\/#website"},"breadcrumb":{"@id":"https:\/\/develop.co.id\/training\/generator-underfrequency-protection-coordination-training\/#breadcrumblist"},"author":{"@id":"https:\/\/develop.co.id\/training\/author\/developtraining\/#author"},"creator":{"@id":"https:\/\/develop.co.id\/training\/author\/developtraining\/#author"},"image":{"@type":"ImageObject","url":"https:\/\/develop.co.id\/training\/wp-content\/uploads\/2026\/08\/generator-underfrequency-protection-coordination-training_9487_74ac1.png","@id":"https:\/\/develop.co.id\/training\/generator-underfrequency-protection-coordination-training\/#mainImage","width":800,"height":600},"primaryImageOfPage":{"@id":"https:\/\/develop.co.id\/training\/generator-underfrequency-protection-coordination-training\/#mainImage"},"datePublished":"2021-11-01T17:40:59+00:00","dateModified":"2026-08-20T06:49:01+00:00"},{"@type":"WebSite","@id":"https:\/\/develop.co.id\/training\/#website","url":"https:\/\/develop.co.id\/training\/","name":"DEVELOP","description":"Oil Gas,Petrochemical, Power Plant,Mining&Industrial Training Specialist","inLanguage":"en-US","publisher":{"@id":"https:\/\/develop.co.id\/training\/#organization"}}]},"og:locale":"en_US","og:site_name":"DEVELOP - Oil Gas,Petrochemical, Power Plant,Mining&amp;Industrial Training Specialist","og:type":"article","og:title":"Generator Underfrequency Protection Coordination Training - DEVELOP","og:description":"Pelajari koordinasi proteksi underfrequency generator untuk mengatur ambang frekuensi, menyelaraskan delay relay, dan menjaga kestabilan sistem pembangkitan.","og:url":"https:\/\/develop.co.id\/training\/generator-underfrequency-protection-coordination-training\/","og:image":"https:\/\/develop.co.id\/training\/wp-content\/uploads\/2026\/07\/DEVELOP-Logo-ls4-300x150-1.png","og:image:secure_url":"https:\/\/develop.co.id\/training\/wp-content\/uploads\/2026\/07\/DEVELOP-Logo-ls4-300x150-1.png","article:published_time":"2021-11-01T17:40:59+00:00","article:modified_time":"2026-08-20T06:49:01+00:00","twitter:card":"summary_large_image","twitter:title":"Generator Underfrequency Protection Coordination Training - DEVELOP","twitter:description":"Pelajari koordinasi proteksi underfrequency generator untuk mengatur ambang frekuensi, menyelaraskan delay relay, dan menjaga kestabilan sistem pembangkitan.","twitter:image":"https:\/\/develop.co.id\/training\/wp-content\/uploads\/2026\/07\/DEVELOP-Logo-ls4-300x150-1.png"},"aioseo_meta_data":{"post_id":"9487","title":null,"description":null,"keywords":null,"keyphrases":{"focus":[],"additional":[]},"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_custom_url":null,"og_image_custom_fields":null,"og_image_url":null,"og_image_width":null,"og_image_height":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":true,"twitter_card":"default","twitter_image_type":"default","twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_image_url":null,"twitter_title":null,"twitter_description":null,"schema_type":"default","schema_type_options":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"","isEnabled":true},"graphs":[]},"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"limit_modified_date":false,"ai":null,"breadcrumb_settings":null,"seo_analyzer_scan_date":null,"created":"2026-08-20 08:35:06","updated":"2026-08-31 13:40:44","focus_keyword":null,"additional_keywords":null,"truseo_locale":null},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/develop.co.id\/training\/\" title=\"Home\">Home<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/develop.co.id\/training\/category\/engineering-technical\/\" title=\"Engineering &amp; Technical\">Engineering &amp; Technical<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/develop.co.id\/training\/category\/engineering-technical\/electrical-engineering\/\" title=\"Electrical Engineering\">Electrical Engineering<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\tGenerator Underfrequency Protection Coordination Training\n\t\t<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"Home","link":"https:\/\/develop.co.id\/training\/"},{"label":"Engineering &amp; Technical","link":"https:\/\/develop.co.id\/training\/category\/engineering-technical\/"},{"label":"Electrical Engineering","link":"https:\/\/develop.co.id\/training\/category\/engineering-technical\/electrical-engineering\/"},{"label":"Generator Underfrequency Protection Coordination Training","link":"https:\/\/develop.co.id\/training\/generator-underfrequency-protection-coordination-training\/"}],"_links":{"self":[{"href":"https:\/\/develop.co.id\/training\/wp-json\/wp\/v2\/posts\/9487","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/develop.co.id\/training\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/develop.co.id\/training\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/develop.co.id\/training\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/develop.co.id\/training\/wp-json\/wp\/v2\/comments?post=9487"}],"version-history":[{"count":0,"href":"https:\/\/develop.co.id\/training\/wp-json\/wp\/v2\/posts\/9487\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/develop.co.id\/training\/wp-json\/wp\/v2\/media\/10043"}],"wp:attachment":[{"href":"https:\/\/develop.co.id\/training\/wp-json\/wp\/v2\/media?parent=9487"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/develop.co.id\/training\/wp-json\/wp\/v2\/categories?post=9487"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/develop.co.id\/training\/wp-json\/wp\/v2\/tags?post=9487"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}