{"id":9351,"date":"2021-02-16T00:26:26","date_gmt":"2021-02-16T00:26:26","guid":{"rendered":"https:\/\/develop.co.id\/training\/auxiliary-relay-in-electrical-protection-training\/"},"modified":"2026-08-20T06:49:06","modified_gmt":"2026-08-20T06:49:06","slug":"auxiliary-relay-in-electrical-protection-training","status":"publish","type":"post","link":"https:\/\/develop.co.id\/training\/auxiliary-relay-in-electrical-protection-training\/","title":{"rendered":"Auxiliary Relay in Electrical Protection Training"},"content":{"rendered":"<p>DEVELOP Training Center menyelenggarakan Kelas Auxiliary Relay in Electrical Protection yang sangat berguna untuk mendapatkan pengetahuan tentang auxiliary relay pada rangkaian proteksi listrik meliputi rating coil, konfigurasi kontak, isolasi sinyal, fungsi trip, alarm, interlock, dan pengujian. <br \/><\/br> Pelatihan dilaksanakan melalui penyampaian materi dan diskusi interaktif di dalam kelas. Peserta pelatihan diajak untuk sepenuhnya aktif dalam memahami materi yang disampaikan oleh instruktur. <br \/><\/br> <center> <img fetchpriority=\"high\" decoding=\"async\" src=\"https:\/\/develop.co.id\/wp-content\/uploads\/2025\/09\/DV-GEN-028.jpg\" alt=\"Auxiliary Relay in Electrical Protection\" width=\"500\" height=\"500\"><figcaption> Auxiliary Relay in Electrical Protection <\/figcaption><\/center> <br \/><\/br> DEVELOP mengimplementasikan Syllabus Kelas Auxiliary Relay in Electrical Protection dengan tahap pembelajaran berkualitas sebagai berikut:<\/p>\n<blockquote><p><b>Sesi 1-2<\/b><\/p>\n<ul>\n<li>Auxiliary relay applications in protection<\/li>\n<li>Relay coil ratings<\/li>\n<li>Contact configurations and ratings<\/li>\n<li>Normally open and closed contacts<\/li>\n<li>Signal multiplication functions<\/li>\n<li>Circuit isolation applications<\/li>\n<li>Trip circuit interfaces<\/li>\n<li>Alarm circuit interfaces<\/li>\n<li>Interlocking relay applications<\/li>\n<li>DC control circuit requirements<\/li>\n<li>Relay mounting and wiring<\/li>\n<li>Case Study<\/li>\n<\/ul>\n<p><b>Sesi 3-4<\/b><\/p>\n<ul>\n<li>Contact switching capacity<\/li>\n<li>Coil energization characteristics<\/li>\n<li>DC voltage variation<\/li>\n<li>Contact bounce considerations<\/li>\n<li>Redundant auxiliary relay arrangements<\/li>\n<li>Protection circuit separation<\/li>\n<li>Breaker interface applications<\/li>\n<li>Lockout and master trip interfaces<\/li>\n<li>Functional relay testing<\/li>\n<li>Contact resistance assessment<\/li>\n<li>Wiring documentation and verification<\/li>\n<li>Case Study<\/li>\n<\/ul>\n<\/blockquote>\n<p><\/br> Sejalan dengan teori yang disampaikan,sebanyak mungkin akan diberikan contoh-contoh studi kasus yang relevan dengan kondisi yang ada diindustri. Dalam hal ini peserta diberikan kesempatan untuk bertanya dan mendiskusikan topik-topik yang dibahas. <br \/><\/br> <center> <img decoding=\"async\" src=\"https:\/\/develop.co.id\/wp-content\/uploads\/2025\/09\/DV-TESTIMONIAL-016.jpg\" alt=\"Auxiliary Relay in Electrical Protection\" width=\"500\" height=\"500\"><figcaption> Auxiliary Relay in Electrical Protection <\/figcaption><\/center> <br \/><\/br> Materi Training dirancang khusus oleh para praktisi dan tenaga ahli yang kompeten serta telah berpengalaman sesuai dengan experience dan solid knowledge  mereka. Anda akan mendapat sharing ilmu langsung dari para praktisi yang berpengalaman bertahun-tahun. <br \/><\/br> Selama training, instruktur kami akan menggunakan kombinasi teori serta praktek langsung dengan studi kasus telah dipersiapkan yang menyerupai Proyek nyata. <br \/><\/br> \n<div class=\"wpcf7 no-js\" id=\"wpcf7-f4427-o1\" lang=\"en-US\" dir=\"ltr\" data-wpcf7-id=\"4427\">\n<div class=\"screen-reader-response\"><p role=\"status\" aria-live=\"polite\" aria-atomic=\"true\"><\/p> <ul><\/ul><\/div>\n<form action=\"\/training\/wp-json\/wp\/v2\/posts\/9351#wpcf7-f4427-o1\" method=\"post\" class=\"wpcf7-form init\" aria-label=\"Contact form\" novalidate=\"novalidate\" data-status=\"init\">\n<fieldset class=\"hidden-fields-container\"><input type=\"hidden\" name=\"_wpcf7\" value=\"4427\" \/><input type=\"hidden\" name=\"_wpcf7_version\" value=\"6.2.5\" \/><input type=\"hidden\" name=\"_wpcf7_locale\" value=\"en_US\" \/><input type=\"hidden\" name=\"_wpcf7_unit_tag\" value=\"wpcf7-f4427-o1\" \/><input type=\"hidden\" name=\"_wpcf7_container_post\" value=\"0\" \/><input type=\"hidden\" name=\"_wpcf7_posted_data_hash\" value=\"\" \/>\n<\/fieldset>\n<blockquote>\n\t<p><b>QUICK REGISTRATION &#10004;<\/b>\n\t<\/p>\n<\/blockquote>\n<div class=\"c-input-group\">\n\t<p><span class=\"wpcf7-form-control-wrap\" data-name=\"your-name\"><input size=\"40\" maxlength=\"400\" class=\"wpcf7-form-control wpcf7-text wpcf7-validates-as-required\" aria-required=\"true\" aria-invalid=\"false\" placeholder=\"Full name\" value=\"\" type=\"text\" name=\"your-name\" \/><\/span><br \/>\n<span class=\"wpcf7-form-control-wrap\" data-name=\"your-email\"><input size=\"40\" maxlength=\"400\" class=\"wpcf7-form-control wpcf7-email wpcf7-validates-as-required wpcf7-text wpcf7-validates-as-email\" aria-required=\"true\" aria-invalid=\"false\" placeholder=\"Email\" value=\"\" type=\"email\" name=\"your-email\" \/><\/span><br \/>\n<span class=\"wpcf7-form-control-wrap\" data-name=\"tel-428\"><input size=\"40\" maxlength=\"400\" class=\"wpcf7-form-control wpcf7-tel wpcf7-validates-as-required wpcf7-text wpcf7-validates-as-tel\" aria-required=\"true\" aria-invalid=\"false\" placeholder=\"Phone\" value=\"\" type=\"tel\" name=\"tel-428\" \/><\/span>\n\t<\/p>\n\t<p><span class=\"wpcf7-form-control-wrap\" data-name=\"your-message\"><textarea cols=\"10\" rows=\"10\" maxlength=\"2000\" class=\"wpcf7-form-control wpcf7-textarea\" aria-invalid=\"false\" placeholder=\"Special message\" name=\"your-message\"><\/textarea><\/span>\n\t<\/p>\n\t<p><span id=\"wpcf7-6b02db7b1a5b2-wrapper\" class=\"wpcf7-form-control-wrap cf7apps-honeypot-wrap honeypot-469-wrap\" data-cf7apps-honeypot=\"honeypot-469\" style=\"position:absolute;width:1px;height:1px;padding:0;margin:-1px;overflow:hidden;clip:rect(0,0,0,0);white-space:nowrap;border:0;\"><input type=\"hidden\" name=\"honeypot-469-random-hash\" value=\"20261122\"><input type=\"hidden\" name=\"honeypot-469-time-token\" value=\"MTc5NTM0OTM3MQ==.37195c22de56edc6db59800fd0faed2acca3ad9a364766d5b3a9d8ff4f57a9d4\"><label\n\t\t    for=\"wpcf7-6b02db7b1a5b2-field\"\n\t\t    class=\"hp-message\"\n        >Please leave this field empty.<\/label><input\n\t    id=\"wpcf7-6b02db7b1a5b2-field\"\n\t    \n\t    class=\"wpcf7-form-control wpcf7-text\"\n\t    type=\"text\"\n\t    name=\"j7k4bslua0vo\"\n\t    value=\"\"\n\t    autocomplete=\"new-password\"\n\t    tabindex=\"1000\"\n\t    data-cf7apps-tabindex=\"1000\"\n    \/><\/span><br \/>\n<input class=\"wpcf7-form-control wpcf7-submit has-spinner\" type=\"submit\" value=\"REGISTER NOW\" \/>\n\t<\/p>\n<\/div><div class=\"wpcf7-response-output\" aria-hidden=\"true\"><\/div>\n<\/form>\n<\/div>\n<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Pelajari teknik auxiliary relay untuk membangun antarmuka rangkaian proteksi yang rapi, terisolasi, andal, dan sesuai kebutuhan trip serta alarm sistem listrik.<\/p>\n","protected":false},"author":1,"featured_media":10062,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_monsterinsights_skip_tracking":false,"footnotes":""},"categories":[34,38],"tags":[193],"class_list":["post-9351","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-electrical-engineering","category-instrument-engineering","tag-electrical-engineering"],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 5.0.5.1 - aioseo.com -->\n\t<meta name=\"description\" content=\"Pelajari teknik auxiliary relay untuk membangun antarmuka rangkaian proteksi yang rapi, terisolasi, andal, dan sesuai kebutuhan trip serta alarm sistem listrik.\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<link rel=\"canonical\" href=\"https:\/\/develop.co.id\/training\/auxiliary-relay-in-electrical-protection-training\/\" \/>\n\t\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 5.0.5.1\" \/>\n\t\t<meta property=\"og:locale\" content=\"en_US\" \/>\n\t\t<meta property=\"og:site_name\" content=\"DEVELOP - Oil Gas,Petrochemical, Power Plant,Mining&amp;Industrial Training Specialist\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"Auxiliary Relay in Electrical Protection Training - DEVELOP\" \/>\n\t\t<meta property=\"og:description\" content=\"Pelajari teknik auxiliary relay untuk membangun antarmuka rangkaian proteksi yang rapi, terisolasi, andal, dan sesuai kebutuhan trip serta alarm sistem listrik.\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/develop.co.id\/training\/auxiliary-relay-in-electrical-protection-training\/\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/develop.co.id\/training\/wp-content\/uploads\/2026\/07\/DEVELOP-Logo-ls4-300x150-1.png\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/develop.co.id\/training\/wp-content\/uploads\/2026\/07\/DEVELOP-Logo-ls4-300x150-1.png\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2021-02-16T00:26:26+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2026-08-20T06:49:06+00:00\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:title\" content=\"Auxiliary Relay in Electrical Protection Training - DEVELOP\" \/>\n\t\t<meta name=\"twitter:description\" content=\"Pelajari teknik auxiliary relay untuk membangun antarmuka rangkaian proteksi yang rapi, terisolasi, andal, dan sesuai kebutuhan trip serta alarm sistem listrik.\" \/>\n\t\t<meta name=\"twitter:image\" content=\"https:\/\/develop.co.id\/training\/wp-content\/uploads\/2026\/07\/DEVELOP-Logo-ls4-300x150-1.png\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"BlogPosting\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/auxiliary-relay-in-electrical-protection-training\\\/#blogposting\",\"name\":\"Auxiliary Relay in Electrical Protection Training - DEVELOP\",\"headline\":\"Auxiliary Relay in Electrical Protection Training\",\"author\":{\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/author\\\/developtraining\\\/#author\"},\"publisher\":{\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/#organization\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/develop.co.id\\\/training\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/auxiliary-relay-in-electrical-protection-training_9351_fde08.png\",\"width\":800,\"height\":600},\"datePublished\":\"2021-02-16T00:26:26+00:00\",\"dateModified\":\"2026-08-20T06:49:06+00:00\",\"inLanguage\":\"en-US\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/auxiliary-relay-in-electrical-protection-training\\\/#webpage\"},\"isPartOf\":{\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/auxiliary-relay-in-electrical-protection-training\\\/#webpage\"},\"articleSection\":\"Electrical Engineering, Instrument Engineering, Electrical Engineering\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/auxiliary-relay-in-electrical-protection-training\\\/#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/#listItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/develop.co.id\\\/training\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/category\\\/engineering-technical\\\/#listItem\",\"name\":\"Engineering &amp; Technical\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/category\\\/engineering-technical\\\/#listItem\",\"position\":2,\"name\":\"Engineering &amp; Technical\",\"item\":\"https:\\\/\\\/develop.co.id\\\/training\\\/category\\\/engineering-technical\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/category\\\/engineering-technical\\\/electrical-engineering\\\/#listItem\",\"name\":\"Electrical Engineering\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/#listItem\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/category\\\/engineering-technical\\\/electrical-engineering\\\/#listItem\",\"position\":3,\"name\":\"Electrical Engineering\",\"item\":\"https:\\\/\\\/develop.co.id\\\/training\\\/category\\\/engineering-technical\\\/electrical-engineering\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/auxiliary-relay-in-electrical-protection-training\\\/#listItem\",\"name\":\"Auxiliary Relay in Electrical Protection Training\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/category\\\/engineering-technical\\\/#listItem\",\"name\":\"Engineering &amp; Technical\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/auxiliary-relay-in-electrical-protection-training\\\/#listItem\",\"position\":4,\"name\":\"Auxiliary Relay in Electrical Protection Training\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/category\\\/engineering-technical\\\/electrical-engineering\\\/#listItem\",\"name\":\"Electrical Engineering\"}}]},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/#organization\",\"name\":\"DEVELOP\",\"description\":\"Oil Gas,Petrochemical, Power Plant,Mining&Industrial Training Specialist\",\"url\":\"https:\\\/\\\/develop.co.id\\\/training\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/develop.co.id\\\/training\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/DEVELOP-Logo-ls4-300x150-1.png\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/auxiliary-relay-in-electrical-protection-training\\\/#organizationLogo\",\"width\":300,\"height\":150},\"image\":{\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/auxiliary-relay-in-electrical-protection-training\\\/#organizationLogo\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/author\\\/developtraining\\\/#author\",\"url\":\"https:\\\/\\\/develop.co.id\\\/training\\\/author\\\/developtraining\\\/\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/auxiliary-relay-in-electrical-protection-training\\\/#authorImage\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/6b88ccabac9c627e76fb131519cdc3ef0e725eb1ff178c0eaa169a92fc8becc5?s=96&d=mm&r=g\",\"width\":96,\"height\":96}},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/auxiliary-relay-in-electrical-protection-training\\\/#webpage\",\"url\":\"https:\\\/\\\/develop.co.id\\\/training\\\/auxiliary-relay-in-electrical-protection-training\\\/\",\"name\":\"Auxiliary Relay in Electrical Protection Training - DEVELOP\",\"description\":\"Pelajari teknik auxiliary relay untuk membangun antarmuka rangkaian proteksi yang rapi, terisolasi, andal, dan sesuai kebutuhan trip serta alarm sistem listrik.\",\"inLanguage\":\"en-US\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/auxiliary-relay-in-electrical-protection-training\\\/#breadcrumblist\"},\"author\":{\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/author\\\/developtraining\\\/#author\"},\"creator\":{\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/author\\\/developtraining\\\/#author\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/develop.co.id\\\/training\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/auxiliary-relay-in-electrical-protection-training_9351_fde08.png\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/auxiliary-relay-in-electrical-protection-training\\\/#mainImage\",\"width\":800,\"height\":600},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/auxiliary-relay-in-electrical-protection-training\\\/#mainImage\"},\"datePublished\":\"2021-02-16T00:26:26+00:00\",\"dateModified\":\"2026-08-20T06:49:06+00:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/#website\",\"url\":\"https:\\\/\\\/develop.co.id\\\/training\\\/\",\"name\":\"DEVELOP\",\"description\":\"Oil Gas,Petrochemical, Power Plant,Mining&Industrial Training Specialist\",\"inLanguage\":\"en-US\",\"publisher\":{\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/#organization\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"Auxiliary Relay in Electrical Protection Training - DEVELOP","description":"Pelajari teknik auxiliary relay untuk membangun antarmuka rangkaian proteksi yang rapi, terisolasi, andal, dan sesuai kebutuhan trip serta alarm sistem listrik.","canonical_url":"https:\/\/develop.co.id\/training\/auxiliary-relay-in-electrical-protection-training\/","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"BlogPosting","@id":"https:\/\/develop.co.id\/training\/auxiliary-relay-in-electrical-protection-training\/#blogposting","name":"Auxiliary Relay in Electrical Protection Training - DEVELOP","headline":"Auxiliary Relay in Electrical Protection Training","author":{"@id":"https:\/\/develop.co.id\/training\/author\/developtraining\/#author"},"publisher":{"@id":"https:\/\/develop.co.id\/training\/#organization"},"image":{"@type":"ImageObject","url":"https:\/\/develop.co.id\/training\/wp-content\/uploads\/2026\/08\/auxiliary-relay-in-electrical-protection-training_9351_fde08.png","width":800,"height":600},"datePublished":"2021-02-16T00:26:26+00:00","dateModified":"2026-08-20T06:49:06+00:00","inLanguage":"en-US","mainEntityOfPage":{"@id":"https:\/\/develop.co.id\/training\/auxiliary-relay-in-electrical-protection-training\/#webpage"},"isPartOf":{"@id":"https:\/\/develop.co.id\/training\/auxiliary-relay-in-electrical-protection-training\/#webpage"},"articleSection":"Electrical Engineering, Instrument Engineering, Electrical Engineering"},{"@type":"BreadcrumbList","@id":"https:\/\/develop.co.id\/training\/auxiliary-relay-in-electrical-protection-training\/#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/develop.co.id\/training\/#listItem","position":1,"name":"Home","item":"https:\/\/develop.co.id\/training\/","nextItem":{"@type":"ListItem","@id":"https:\/\/develop.co.id\/training\/category\/engineering-technical\/#listItem","name":"Engineering &amp; Technical"}},{"@type":"ListItem","@id":"https:\/\/develop.co.id\/training\/category\/engineering-technical\/#listItem","position":2,"name":"Engineering &amp; Technical","item":"https:\/\/develop.co.id\/training\/category\/engineering-technical\/","nextItem":{"@type":"ListItem","@id":"https:\/\/develop.co.id\/training\/category\/engineering-technical\/electrical-engineering\/#listItem","name":"Electrical Engineering"},"previousItem":{"@type":"ListItem","@id":"https:\/\/develop.co.id\/training\/#listItem","name":"Home"}},{"@type":"ListItem","@id":"https:\/\/develop.co.id\/training\/category\/engineering-technical\/electrical-engineering\/#listItem","position":3,"name":"Electrical Engineering","item":"https:\/\/develop.co.id\/training\/category\/engineering-technical\/electrical-engineering\/","nextItem":{"@type":"ListItem","@id":"https:\/\/develop.co.id\/training\/auxiliary-relay-in-electrical-protection-training\/#listItem","name":"Auxiliary Relay in Electrical Protection Training"},"previousItem":{"@type":"ListItem","@id":"https:\/\/develop.co.id\/training\/category\/engineering-technical\/#listItem","name":"Engineering &amp; Technical"}},{"@type":"ListItem","@id":"https:\/\/develop.co.id\/training\/auxiliary-relay-in-electrical-protection-training\/#listItem","position":4,"name":"Auxiliary Relay in Electrical Protection Training","previousItem":{"@type":"ListItem","@id":"https:\/\/develop.co.id\/training\/category\/engineering-technical\/electrical-engineering\/#listItem","name":"Electrical Engineering"}}]},{"@type":"Organization","@id":"https:\/\/develop.co.id\/training\/#organization","name":"DEVELOP","description":"Oil Gas,Petrochemical, Power Plant,Mining&Industrial Training Specialist","url":"https:\/\/develop.co.id\/training\/","logo":{"@type":"ImageObject","url":"https:\/\/develop.co.id\/training\/wp-content\/uploads\/2026\/07\/DEVELOP-Logo-ls4-300x150-1.png","@id":"https:\/\/develop.co.id\/training\/auxiliary-relay-in-electrical-protection-training\/#organizationLogo","width":300,"height":150},"image":{"@id":"https:\/\/develop.co.id\/training\/auxiliary-relay-in-electrical-protection-training\/#organizationLogo"}},{"@type":"Person","@id":"https:\/\/develop.co.id\/training\/author\/developtraining\/#author","url":"https:\/\/develop.co.id\/training\/author\/developtraining\/","image":{"@type":"ImageObject","@id":"https:\/\/develop.co.id\/training\/auxiliary-relay-in-electrical-protection-training\/#authorImage","url":"https:\/\/secure.gravatar.com\/avatar\/6b88ccabac9c627e76fb131519cdc3ef0e725eb1ff178c0eaa169a92fc8becc5?s=96&d=mm&r=g","width":96,"height":96}},{"@type":"WebPage","@id":"https:\/\/develop.co.id\/training\/auxiliary-relay-in-electrical-protection-training\/#webpage","url":"https:\/\/develop.co.id\/training\/auxiliary-relay-in-electrical-protection-training\/","name":"Auxiliary Relay in Electrical Protection Training - DEVELOP","description":"Pelajari teknik auxiliary relay untuk membangun antarmuka rangkaian proteksi yang rapi, terisolasi, andal, dan sesuai kebutuhan trip serta alarm sistem listrik.","inLanguage":"en-US","isPartOf":{"@id":"https:\/\/develop.co.id\/training\/#website"},"breadcrumb":{"@id":"https:\/\/develop.co.id\/training\/auxiliary-relay-in-electrical-protection-training\/#breadcrumblist"},"author":{"@id":"https:\/\/develop.co.id\/training\/author\/developtraining\/#author"},"creator":{"@id":"https:\/\/develop.co.id\/training\/author\/developtraining\/#author"},"image":{"@type":"ImageObject","url":"https:\/\/develop.co.id\/training\/wp-content\/uploads\/2026\/08\/auxiliary-relay-in-electrical-protection-training_9351_fde08.png","@id":"https:\/\/develop.co.id\/training\/auxiliary-relay-in-electrical-protection-training\/#mainImage","width":800,"height":600},"primaryImageOfPage":{"@id":"https:\/\/develop.co.id\/training\/auxiliary-relay-in-electrical-protection-training\/#mainImage"},"datePublished":"2021-02-16T00:26:26+00:00","dateModified":"2026-08-20T06:49:06+00:00"},{"@type":"WebSite","@id":"https:\/\/develop.co.id\/training\/#website","url":"https:\/\/develop.co.id\/training\/","name":"DEVELOP","description":"Oil Gas,Petrochemical, Power Plant,Mining&Industrial Training Specialist","inLanguage":"en-US","publisher":{"@id":"https:\/\/develop.co.id\/training\/#organization"}}]},"og:locale":"en_US","og:site_name":"DEVELOP - Oil Gas,Petrochemical, Power Plant,Mining&amp;Industrial Training Specialist","og:type":"article","og:title":"Auxiliary Relay in Electrical Protection Training - DEVELOP","og:description":"Pelajari teknik auxiliary relay untuk membangun antarmuka rangkaian proteksi yang rapi, terisolasi, andal, dan sesuai kebutuhan trip serta alarm sistem listrik.","og:url":"https:\/\/develop.co.id\/training\/auxiliary-relay-in-electrical-protection-training\/","og:image":"https:\/\/develop.co.id\/training\/wp-content\/uploads\/2026\/07\/DEVELOP-Logo-ls4-300x150-1.png","og:image:secure_url":"https:\/\/develop.co.id\/training\/wp-content\/uploads\/2026\/07\/DEVELOP-Logo-ls4-300x150-1.png","article:published_time":"2021-02-16T00:26:26+00:00","article:modified_time":"2026-08-20T06:49:06+00:00","twitter:card":"summary_large_image","twitter:title":"Auxiliary Relay in Electrical Protection Training - DEVELOP","twitter:description":"Pelajari teknik auxiliary relay untuk membangun antarmuka rangkaian proteksi yang rapi, terisolasi, andal, dan sesuai kebutuhan trip serta alarm sistem listrik.","twitter:image":"https:\/\/develop.co.id\/training\/wp-content\/uploads\/2026\/07\/DEVELOP-Logo-ls4-300x150-1.png"},"aioseo_meta_data":{"post_id":"9351","title":null,"description":null,"keywords":null,"keyphrases":{"focus":[],"additional":[]},"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_custom_url":null,"og_image_custom_fields":null,"og_image_url":null,"og_image_width":null,"og_image_height":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":true,"twitter_card":"default","twitter_image_type":"default","twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_image_url":null,"twitter_title":null,"twitter_description":null,"schema_type":"default","schema_type_options":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"","isEnabled":true},"graphs":[]},"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"limit_modified_date":false,"ai":null,"breadcrumb_settings":null,"seo_analyzer_scan_date":null,"created":"2026-08-20 08:12:01","updated":"2026-08-31 13:40:49","focus_keyword":null,"additional_keywords":null,"truseo_locale":null},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/develop.co.id\/training\/\" title=\"Home\">Home<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/develop.co.id\/training\/category\/engineering-technical\/\" title=\"Engineering &amp; Technical\">Engineering &amp; Technical<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/develop.co.id\/training\/category\/engineering-technical\/electrical-engineering\/\" title=\"Electrical Engineering\">Electrical Engineering<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\tAuxiliary Relay in Electrical Protection Training\n\t\t<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"Home","link":"https:\/\/develop.co.id\/training\/"},{"label":"Engineering &amp; Technical","link":"https:\/\/develop.co.id\/training\/category\/engineering-technical\/"},{"label":"Electrical Engineering","link":"https:\/\/develop.co.id\/training\/category\/engineering-technical\/electrical-engineering\/"},{"label":"Auxiliary Relay in Electrical Protection Training","link":"https:\/\/develop.co.id\/training\/auxiliary-relay-in-electrical-protection-training\/"}],"_links":{"self":[{"href":"https:\/\/develop.co.id\/training\/wp-json\/wp\/v2\/posts\/9351","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/develop.co.id\/training\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/develop.co.id\/training\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/develop.co.id\/training\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/develop.co.id\/training\/wp-json\/wp\/v2\/comments?post=9351"}],"version-history":[{"count":0,"href":"https:\/\/develop.co.id\/training\/wp-json\/wp\/v2\/posts\/9351\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/develop.co.id\/training\/wp-json\/wp\/v2\/media\/10062"}],"wp:attachment":[{"href":"https:\/\/develop.co.id\/training\/wp-json\/wp\/v2\/media?parent=9351"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/develop.co.id\/training\/wp-json\/wp\/v2\/categories?post=9351"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/develop.co.id\/training\/wp-json\/wp\/v2\/tags?post=9351"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}