{"id":8402,"date":"2020-06-06T06:55:11","date_gmt":"2020-06-06T06:55:11","guid":{"rendered":"https:\/\/develop.co.id\/training\/breaker-failure-protection-relays-with-50bf-functions-training\/"},"modified":"2026-08-15T09:02:05","modified_gmt":"2026-08-15T09:02:05","slug":"breaker-failure-protection-relays-with-50bf-functions-training","status":"publish","type":"post","link":"https:\/\/develop.co.id\/training\/breaker-failure-protection-relays-with-50bf-functions-training\/","title":{"rendered":"Breaker-Failure Protection Relays with 50BF Functions Training"},"content":{"rendered":"<p>DEVELOP Training Center menyelenggarakan Kelas Breaker-Failure Protection Relays with 50BF Functions yang sangat berguna untuk mendapatkan pengetahuan tentang proteksi kegagalan breaker fungsi 50BF, deteksi arus, waktu operasi, jalur trip cadangan, kontak bantu, logika lockout, isolasi breaker, dan pengujian respons relay. <br \/><\/br> Pelatihan diselenggarakan melalui pemaparan materi dan diskusi interaktif di dalam kelas. Peserta didorong untuk berpartisipasi aktif dalam memahami materi yang disampaikan oleh instruktur. <br \/><\/br> <center> <img fetchpriority=\"high\" decoding=\"async\" class=\"aligncenter size-full wp-image-6397\" src=\"https:\/\/develop.co.id\/wp-content\/uploads\/2025\/07\/DV-TESTIMONIAL-028.jpg\" alt=\"Breaker-Failure Protection Relays with 50BF Functions\" width=\"300\" height=\"300\"><figcaption> Breaker-Failure Protection Relays with 50BF Functions <\/figcaption><\/center> <br \/><\/br> DEVELOP mengimplementasikan Syllabus Kelas Breaker-Failure Protection Relays with 50BF Functions dengan tahap pembelajaran berkualitas sebagai berikut:<\/p>\n<blockquote><p><b>Sesi 1-2<\/b><\/p>\n<ul>\n<li>Circuit breaker operation and failure conditions<\/li>\n<li>ANSI 50BF breaker-failure protection characteristics<\/li>\n<li>Breaker current detection and trip initiation<\/li>\n<li>Breaker-failure timer and operating thresholds<\/li>\n<li>Backup trip paths and adjacent breaker isolation<\/li>\n<li>Current transformer input circuits and phase detection<\/li>\n<li>Breaker auxiliary contacts and status inputs<\/li>\n<li>Trip logic, lockout functions, and backup isolation<\/li>\n<li>Case Study<\/li>\n<\/ul>\n<p> <b>Sesi 3-4<\/b><\/p>\n<ul>\n<li>50BF relay configuration and timer setting verification<\/li>\n<li>Trip initiation and breaker current injection testing<\/li>\n<li>Breaker-failure timer response testing<\/li>\n<li>Successful breaker clearing response verification<\/li>\n<li>Failure condition and backup trip testing<\/li>\n<li>Trip output and adjacent breaker circuit validation<\/li>\n<li>Relay response assessment and setting refinement<\/li>\n<li>Case Study<\/li>\n<\/ul>\n<\/blockquote>\n<p><\/br> Sejalan dengan teori yang disampaikan, akan disertakan sebanyak mungkin studi kasus yang relevan dengan kondisi industri saat ini. Peserta juga diberikan kesempatan untuk bertanya dan berdiskusi terkait topik yang dibahas. <br \/><\/br> <center> <img decoding=\"async\" class=\"aligncenter size-full wp-image-23813\" src=\"https:\/\/develop.co.id\/wp-content\/uploads\/2025\/07\/DV-TESTIMONIAL-028.jpg\" alt=\"Breaker-Failure Protection Relays with 50BF Functions\" width=\"400\" height=\"400\"><figcaption> Breaker-Failure Protection Relays with 50BF Functions <\/figcaption><\/center> <br \/><\/br> Materi Training dirancang khusus oleh para praktisi dan tenaga ahli yang kompeten serta telah berpengalaman sesuai dengan experience dan solid knowledge  mereka. Anda akan mendapat sharing ilmu langsung dari para praktisi yang berpengalaman bertahun-tahun. <br \/><\/br> Selama training, instruktur kami akan menggunakan kombinasi teori serta praktek langsung dengan studi kasus telah dipersiapkan yang menyerupai Proyek nyata. <br \/><\/br> \n<div class=\"wpcf7 no-js\" id=\"wpcf7-f4427-o1\" lang=\"en-US\" dir=\"ltr\" data-wpcf7-id=\"4427\">\n<div class=\"screen-reader-response\"><p role=\"status\" aria-live=\"polite\" aria-atomic=\"true\"><\/p> <ul><\/ul><\/div>\n<form action=\"\/training\/wp-json\/wp\/v2\/posts\/8402#wpcf7-f4427-o1\" method=\"post\" class=\"wpcf7-form init\" aria-label=\"Contact form\" novalidate=\"novalidate\" data-status=\"init\">\n<fieldset class=\"hidden-fields-container\"><input type=\"hidden\" name=\"_wpcf7\" value=\"4427\" \/><input type=\"hidden\" name=\"_wpcf7_version\" value=\"6.2.5\" \/><input type=\"hidden\" name=\"_wpcf7_locale\" value=\"en_US\" \/><input type=\"hidden\" name=\"_wpcf7_unit_tag\" value=\"wpcf7-f4427-o1\" \/><input type=\"hidden\" name=\"_wpcf7_container_post\" value=\"0\" \/><input type=\"hidden\" name=\"_wpcf7_posted_data_hash\" value=\"\" \/>\n<\/fieldset>\n<blockquote>\n\t<p><b>QUICK REGISTRATION &#10004;<\/b>\n\t<\/p>\n<\/blockquote>\n<div class=\"c-input-group\">\n\t<p><span class=\"wpcf7-form-control-wrap\" data-name=\"your-name\"><input size=\"40\" maxlength=\"400\" class=\"wpcf7-form-control wpcf7-text wpcf7-validates-as-required\" aria-required=\"true\" aria-invalid=\"false\" placeholder=\"Full name\" value=\"\" type=\"text\" name=\"your-name\" \/><\/span><br \/>\n<span class=\"wpcf7-form-control-wrap\" data-name=\"your-email\"><input size=\"40\" maxlength=\"400\" class=\"wpcf7-form-control wpcf7-email wpcf7-validates-as-required wpcf7-text wpcf7-validates-as-email\" aria-required=\"true\" aria-invalid=\"false\" placeholder=\"Email\" value=\"\" type=\"email\" name=\"your-email\" \/><\/span><br \/>\n<span class=\"wpcf7-form-control-wrap\" data-name=\"tel-428\"><input size=\"40\" maxlength=\"400\" class=\"wpcf7-form-control wpcf7-tel wpcf7-validates-as-required wpcf7-text wpcf7-validates-as-tel\" aria-required=\"true\" aria-invalid=\"false\" placeholder=\"Phone\" value=\"\" type=\"tel\" name=\"tel-428\" \/><\/span>\n\t<\/p>\n\t<p><span class=\"wpcf7-form-control-wrap\" data-name=\"your-message\"><textarea cols=\"10\" rows=\"10\" maxlength=\"2000\" class=\"wpcf7-form-control wpcf7-textarea\" aria-invalid=\"false\" placeholder=\"Special message\" name=\"your-message\"><\/textarea><\/span>\n\t<\/p>\n\t<p><input class=\"wpcf7-form-control wpcf7-submit has-spinner\" type=\"submit\" value=\"REGISTER NOW\" \/>\n\t<\/p>\n<\/div><div class=\"wpcf7-response-output\" aria-hidden=\"true\"><\/div>\n<\/form>\n<\/div>\n<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Pelajari teknik proteksi breaker-failure 50BF untuk meningkatkan kemampuan setting timer, pengujian trip cadangan, verifikasi breaker, dan evaluasi isolasi sistem.<\/p>\n","protected":false},"author":1,"featured_media":8629,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"om_disable_all_campaigns":false,"_monsterinsights_skip_tracking":false,"footnotes":""},"categories":[34,38],"tags":[8628,8623,8631,8625,8622,8630,8626,8629,8624,193,8627],"class_list":["post-8402","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-electrical-engineering","category-instrument-engineering","tag-50bf-relay-settings","tag-ansi-50bf-protection","tag-backup-protection-relay","tag-backup-trip-relay","tag-breaker-failure-relay","tag-breaker-failure-testing","tag-breaker-failure-timer","tag-breaker-trip-circuit","tag-circuit-breaker-failure-protection","tag-electrical-engineering","tag-substation-breaker-protection"],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 5.0.5.1 - aioseo.com -->\n\t<meta name=\"description\" content=\"Pelajari teknik proteksi breaker-failure 50BF untuk meningkatkan kemampuan setting timer, pengujian trip cadangan, verifikasi breaker, dan evaluasi isolasi sistem.\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<link rel=\"canonical\" href=\"https:\/\/develop.co.id\/training\/breaker-failure-protection-relays-with-50bf-functions-training\/\" \/>\n\t\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 5.0.5.1\" \/>\n\t\t<meta property=\"og:locale\" content=\"en_US\" \/>\n\t\t<meta property=\"og:site_name\" content=\"DEVELOP - Oil Gas,Petrochemical, Power Plant,Mining&amp;Industrial Training Specialist\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"Breaker-Failure Protection Relays with 50BF Functions Training - DEVELOP\" \/>\n\t\t<meta property=\"og:description\" content=\"Pelajari teknik proteksi breaker-failure 50BF untuk meningkatkan kemampuan setting timer, pengujian trip cadangan, verifikasi breaker, dan evaluasi isolasi sistem.\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/develop.co.id\/training\/breaker-failure-protection-relays-with-50bf-functions-training\/\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/develop.co.id\/training\/wp-content\/uploads\/2026\/11\/develop-co-id-32-light-blue-300px.jpg\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/develop.co.id\/training\/wp-content\/uploads\/2026\/11\/develop-co-id-32-light-blue-300px.jpg\" \/>\n\t\t<meta property=\"og:image:width\" content=\"300\" \/>\n\t\t<meta property=\"og:image:height\" content=\"300\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2020-06-06T06:55:11+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2026-08-15T09:02:05+00:00\" \/>\n\t\t<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/sertifikasikerja\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:site\" content=\"@oilgascourse\" \/>\n\t\t<meta name=\"twitter:title\" content=\"Breaker-Failure Protection Relays with 50BF Functions Training - DEVELOP\" \/>\n\t\t<meta name=\"twitter:description\" content=\"Pelajari teknik proteksi breaker-failure 50BF untuk meningkatkan kemampuan setting timer, pengujian trip cadangan, verifikasi breaker, dan evaluasi isolasi sistem.\" \/>\n\t\t<meta name=\"twitter:creator\" content=\"@oilgascourse\" \/>\n\t\t<meta name=\"twitter:image\" content=\"https:\/\/develop.co.id\/training\/wp-content\/uploads\/2026\/11\/develop-co-id-32-light-blue-300px.jpg\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"BlogPosting\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/breaker-failure-protection-relays-with-50bf-functions-training\\\/#blogposting\",\"name\":\"Breaker-Failure Protection Relays with 50BF Functions Training - DEVELOP\",\"headline\":\"Breaker-Failure Protection Relays with 50BF Functions Training\",\"author\":{\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/author\\\/developtraining\\\/#author\"},\"publisher\":{\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/#organization\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/develop.co.id\\\/training\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/breaker-failure-protection-relays-with-50bf-functions-training_8402_1ca57.png\",\"width\":800,\"height\":600},\"datePublished\":\"2020-06-06T06:55:11+00:00\",\"dateModified\":\"2026-08-15T09:02:05+00:00\",\"inLanguage\":\"en-US\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/breaker-failure-protection-relays-with-50bf-functions-training\\\/#webpage\"},\"isPartOf\":{\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/breaker-failure-protection-relays-with-50bf-functions-training\\\/#webpage\"},\"articleSection\":\"Electrical Engineering, Instrument Engineering, 50BF relay settings, ANSI 50BF protection, backup protection relay, backup trip relay, breaker failure relay, breaker failure testing, breaker failure timer, breaker trip circuit, circuit breaker failure protection, Electrical Engineering, substation breaker protection\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/breaker-failure-protection-relays-with-50bf-functions-training\\\/#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/#listItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/develop.co.id\\\/training\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/category\\\/engineering-technical\\\/#listItem\",\"name\":\"Engineering &amp; Technical\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/category\\\/engineering-technical\\\/#listItem\",\"position\":2,\"name\":\"Engineering &amp; Technical\",\"item\":\"https:\\\/\\\/develop.co.id\\\/training\\\/category\\\/engineering-technical\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/category\\\/engineering-technical\\\/electrical-engineering\\\/#listItem\",\"name\":\"Electrical Engineering\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/#listItem\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/category\\\/engineering-technical\\\/electrical-engineering\\\/#listItem\",\"position\":3,\"name\":\"Electrical Engineering\",\"item\":\"https:\\\/\\\/develop.co.id\\\/training\\\/category\\\/engineering-technical\\\/electrical-engineering\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/breaker-failure-protection-relays-with-50bf-functions-training\\\/#listItem\",\"name\":\"Breaker-Failure Protection Relays with 50BF Functions Training\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/category\\\/engineering-technical\\\/#listItem\",\"name\":\"Engineering &amp; Technical\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/breaker-failure-protection-relays-with-50bf-functions-training\\\/#listItem\",\"position\":4,\"name\":\"Breaker-Failure Protection Relays with 50BF Functions Training\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/category\\\/engineering-technical\\\/electrical-engineering\\\/#listItem\",\"name\":\"Electrical Engineering\"}}]},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/#organization\",\"name\":\"DEVELOP\",\"description\":\"Oil Gas,Petrochemical, Power Plant,Mining&Industrial Training Specialist\",\"url\":\"https:\\\/\\\/develop.co.id\\\/training\\\/\",\"telephone\":\"+628159147070\",\"logo\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/develop.co.id\\\/training\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/develop-co-id-32-light-blue-300px.jpg\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/breaker-failure-protection-relays-with-50bf-functions-training\\\/#organizationLogo\",\"width\":300,\"height\":300},\"image\":{\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/breaker-failure-protection-relays-with-50bf-functions-training\\\/#organizationLogo\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/sertifikasikerja\",\"https:\\\/\\\/x.com\\\/oilgascourse\",\"https:\\\/\\\/www.instagram.com\\\/developtrainingofficial\",\"https:\\\/\\\/tiktok.com\\\/@develop.course\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/develop-course\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/author\\\/developtraining\\\/#author\",\"url\":\"https:\\\/\\\/develop.co.id\\\/training\\\/author\\\/developtraining\\\/\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/breaker-failure-protection-relays-with-50bf-functions-training\\\/#authorImage\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/6b88ccabac9c627e76fb131519cdc3ef0e725eb1ff178c0eaa169a92fc8becc5?s=96&d=mm&r=g\",\"width\":96,\"height\":96}},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/breaker-failure-protection-relays-with-50bf-functions-training\\\/#webpage\",\"url\":\"https:\\\/\\\/develop.co.id\\\/training\\\/breaker-failure-protection-relays-with-50bf-functions-training\\\/\",\"name\":\"Breaker-Failure Protection Relays with 50BF Functions Training - DEVELOP\",\"description\":\"Pelajari teknik proteksi breaker-failure 50BF untuk meningkatkan kemampuan setting timer, pengujian trip cadangan, verifikasi breaker, dan evaluasi isolasi sistem.\",\"inLanguage\":\"en-US\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/breaker-failure-protection-relays-with-50bf-functions-training\\\/#breadcrumblist\"},\"author\":{\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/author\\\/developtraining\\\/#author\"},\"creator\":{\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/author\\\/developtraining\\\/#author\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/develop.co.id\\\/training\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/breaker-failure-protection-relays-with-50bf-functions-training_8402_1ca57.png\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/breaker-failure-protection-relays-with-50bf-functions-training\\\/#mainImage\",\"width\":800,\"height\":600},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/breaker-failure-protection-relays-with-50bf-functions-training\\\/#mainImage\"},\"datePublished\":\"2020-06-06T06:55:11+00:00\",\"dateModified\":\"2026-08-15T09:02:05+00:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/#website\",\"url\":\"https:\\\/\\\/develop.co.id\\\/training\\\/\",\"name\":\"DEVELOP\",\"description\":\"Oil Gas,Petrochemical, Power Plant,Mining&Industrial Training Specialist\",\"inLanguage\":\"en-US\",\"publisher\":{\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/#organization\"}}]}\n\t\t<\/script>\n\t\t<script type=\"text\/javascript\">\n\t\t\t(function(c,l,a,r,i,t,y){\n\t\t\tc[a]=c[a]||function(){(c[a].q=c[a].q||[]).push(arguments)};t=l.createElement(r);t.async=1;\n\t\t\tt.src=\"https:\/\/www.clarity.ms\/tag\/\"+i+\"?ref=aioseo\";y=l.getElementsByTagName(r)[0];y.parentNode.insertBefore(t,y);\n\t\t})(window, document, \"clarity\", \"script\", \"zdv8xzjv86\");\n\t\t<\/script>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"Breaker-Failure Protection Relays with 50BF Functions Training - DEVELOP","description":"Pelajari teknik proteksi breaker-failure 50BF untuk meningkatkan kemampuan setting timer, pengujian trip cadangan, verifikasi breaker, dan evaluasi isolasi sistem.","canonical_url":"https:\/\/develop.co.id\/training\/breaker-failure-protection-relays-with-50bf-functions-training\/","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"BlogPosting","@id":"https:\/\/develop.co.id\/training\/breaker-failure-protection-relays-with-50bf-functions-training\/#blogposting","name":"Breaker-Failure Protection Relays with 50BF Functions Training - DEVELOP","headline":"Breaker-Failure Protection Relays with 50BF Functions Training","author":{"@id":"https:\/\/develop.co.id\/training\/author\/developtraining\/#author"},"publisher":{"@id":"https:\/\/develop.co.id\/training\/#organization"},"image":{"@type":"ImageObject","url":"https:\/\/develop.co.id\/training\/wp-content\/uploads\/2026\/08\/breaker-failure-protection-relays-with-50bf-functions-training_8402_1ca57.png","width":800,"height":600},"datePublished":"2020-06-06T06:55:11+00:00","dateModified":"2026-08-15T09:02:05+00:00","inLanguage":"en-US","mainEntityOfPage":{"@id":"https:\/\/develop.co.id\/training\/breaker-failure-protection-relays-with-50bf-functions-training\/#webpage"},"isPartOf":{"@id":"https:\/\/develop.co.id\/training\/breaker-failure-protection-relays-with-50bf-functions-training\/#webpage"},"articleSection":"Electrical Engineering, Instrument Engineering, 50BF relay settings, ANSI 50BF protection, backup protection relay, backup trip relay, breaker failure relay, breaker failure testing, breaker failure timer, breaker trip circuit, circuit breaker failure protection, Electrical Engineering, substation breaker protection"},{"@type":"BreadcrumbList","@id":"https:\/\/develop.co.id\/training\/breaker-failure-protection-relays-with-50bf-functions-training\/#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/develop.co.id\/training\/#listItem","position":1,"name":"Home","item":"https:\/\/develop.co.id\/training\/","nextItem":{"@type":"ListItem","@id":"https:\/\/develop.co.id\/training\/category\/engineering-technical\/#listItem","name":"Engineering &amp; Technical"}},{"@type":"ListItem","@id":"https:\/\/develop.co.id\/training\/category\/engineering-technical\/#listItem","position":2,"name":"Engineering &amp; Technical","item":"https:\/\/develop.co.id\/training\/category\/engineering-technical\/","nextItem":{"@type":"ListItem","@id":"https:\/\/develop.co.id\/training\/category\/engineering-technical\/electrical-engineering\/#listItem","name":"Electrical Engineering"},"previousItem":{"@type":"ListItem","@id":"https:\/\/develop.co.id\/training\/#listItem","name":"Home"}},{"@type":"ListItem","@id":"https:\/\/develop.co.id\/training\/category\/engineering-technical\/electrical-engineering\/#listItem","position":3,"name":"Electrical Engineering","item":"https:\/\/develop.co.id\/training\/category\/engineering-technical\/electrical-engineering\/","nextItem":{"@type":"ListItem","@id":"https:\/\/develop.co.id\/training\/breaker-failure-protection-relays-with-50bf-functions-training\/#listItem","name":"Breaker-Failure Protection Relays with 50BF Functions Training"},"previousItem":{"@type":"ListItem","@id":"https:\/\/develop.co.id\/training\/category\/engineering-technical\/#listItem","name":"Engineering &amp; Technical"}},{"@type":"ListItem","@id":"https:\/\/develop.co.id\/training\/breaker-failure-protection-relays-with-50bf-functions-training\/#listItem","position":4,"name":"Breaker-Failure Protection Relays with 50BF Functions Training","previousItem":{"@type":"ListItem","@id":"https:\/\/develop.co.id\/training\/category\/engineering-technical\/electrical-engineering\/#listItem","name":"Electrical Engineering"}}]},{"@type":"Organization","@id":"https:\/\/develop.co.id\/training\/#organization","name":"DEVELOP","description":"Oil Gas,Petrochemical, Power Plant,Mining&Industrial Training Specialist","url":"https:\/\/develop.co.id\/training\/","telephone":"+628159147070","logo":{"@type":"ImageObject","url":"https:\/\/develop.co.id\/training\/wp-content\/uploads\/2026\/11\/develop-co-id-32-light-blue-300px.jpg","@id":"https:\/\/develop.co.id\/training\/breaker-failure-protection-relays-with-50bf-functions-training\/#organizationLogo","width":300,"height":300},"image":{"@id":"https:\/\/develop.co.id\/training\/breaker-failure-protection-relays-with-50bf-functions-training\/#organizationLogo"},"sameAs":["https:\/\/www.facebook.com\/sertifikasikerja","https:\/\/x.com\/oilgascourse","https:\/\/www.instagram.com\/developtrainingofficial","https:\/\/tiktok.com\/@develop.course","https:\/\/www.linkedin.com\/company\/develop-course"]},{"@type":"Person","@id":"https:\/\/develop.co.id\/training\/author\/developtraining\/#author","url":"https:\/\/develop.co.id\/training\/author\/developtraining\/","image":{"@type":"ImageObject","@id":"https:\/\/develop.co.id\/training\/breaker-failure-protection-relays-with-50bf-functions-training\/#authorImage","url":"https:\/\/secure.gravatar.com\/avatar\/6b88ccabac9c627e76fb131519cdc3ef0e725eb1ff178c0eaa169a92fc8becc5?s=96&d=mm&r=g","width":96,"height":96}},{"@type":"WebPage","@id":"https:\/\/develop.co.id\/training\/breaker-failure-protection-relays-with-50bf-functions-training\/#webpage","url":"https:\/\/develop.co.id\/training\/breaker-failure-protection-relays-with-50bf-functions-training\/","name":"Breaker-Failure Protection Relays with 50BF Functions Training - DEVELOP","description":"Pelajari teknik proteksi breaker-failure 50BF untuk meningkatkan kemampuan setting timer, pengujian trip cadangan, verifikasi breaker, dan evaluasi isolasi sistem.","inLanguage":"en-US","isPartOf":{"@id":"https:\/\/develop.co.id\/training\/#website"},"breadcrumb":{"@id":"https:\/\/develop.co.id\/training\/breaker-failure-protection-relays-with-50bf-functions-training\/#breadcrumblist"},"author":{"@id":"https:\/\/develop.co.id\/training\/author\/developtraining\/#author"},"creator":{"@id":"https:\/\/develop.co.id\/training\/author\/developtraining\/#author"},"image":{"@type":"ImageObject","url":"https:\/\/develop.co.id\/training\/wp-content\/uploads\/2026\/08\/breaker-failure-protection-relays-with-50bf-functions-training_8402_1ca57.png","@id":"https:\/\/develop.co.id\/training\/breaker-failure-protection-relays-with-50bf-functions-training\/#mainImage","width":800,"height":600},"primaryImageOfPage":{"@id":"https:\/\/develop.co.id\/training\/breaker-failure-protection-relays-with-50bf-functions-training\/#mainImage"},"datePublished":"2020-06-06T06:55:11+00:00","dateModified":"2026-08-15T09:02:05+00:00"},{"@type":"WebSite","@id":"https:\/\/develop.co.id\/training\/#website","url":"https:\/\/develop.co.id\/training\/","name":"DEVELOP","description":"Oil Gas,Petrochemical, Power Plant,Mining&Industrial Training Specialist","inLanguage":"en-US","publisher":{"@id":"https:\/\/develop.co.id\/training\/#organization"}}]},"og:locale":"en_US","og:site_name":"DEVELOP - Oil Gas,Petrochemical, Power Plant,Mining&amp;Industrial Training Specialist","og:type":"article","og:title":"Breaker-Failure Protection Relays with 50BF Functions Training - DEVELOP","og:description":"Pelajari teknik proteksi breaker-failure 50BF untuk meningkatkan kemampuan setting timer, pengujian trip cadangan, verifikasi breaker, dan evaluasi isolasi sistem.","og:url":"https:\/\/develop.co.id\/training\/breaker-failure-protection-relays-with-50bf-functions-training\/","og:image":"https:\/\/develop.co.id\/training\/wp-content\/uploads\/2026\/11\/develop-co-id-32-light-blue-300px.jpg","og:image:secure_url":"https:\/\/develop.co.id\/training\/wp-content\/uploads\/2026\/11\/develop-co-id-32-light-blue-300px.jpg","og:image:width":300,"og:image:height":300,"article:published_time":"2020-06-06T06:55:11+00:00","article:modified_time":"2026-08-15T09:02:05+00:00","article:publisher":"https:\/\/www.facebook.com\/sertifikasikerja","twitter:card":"summary_large_image","twitter:site":"@oilgascourse","twitter:title":"Breaker-Failure Protection Relays with 50BF Functions Training - DEVELOP","twitter:description":"Pelajari teknik proteksi breaker-failure 50BF untuk meningkatkan kemampuan setting timer, pengujian trip cadangan, verifikasi breaker, dan evaluasi isolasi sistem.","twitter:creator":"@oilgascourse","twitter:image":"https:\/\/develop.co.id\/training\/wp-content\/uploads\/2026\/11\/develop-co-id-32-light-blue-300px.jpg"},"aioseo_meta_data":{"post_id":"8402","title":null,"description":null,"keywords":null,"keyphrases":{"focus":[],"additional":[]},"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_custom_url":null,"og_image_custom_fields":null,"og_image_url":null,"og_image_width":null,"og_image_height":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":true,"twitter_card":"default","twitter_image_type":"default","twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_image_url":null,"twitter_title":null,"twitter_description":null,"schema_type":"default","schema_type_options":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"","isEnabled":true},"graphs":[]},"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"limit_modified_date":false,"ai":null,"breadcrumb_settings":null,"seo_analyzer_scan_date":null,"created":"2026-08-15 09:01:54","updated":"2026-08-15 09:11:02","focus_keyword":null,"additional_keywords":null,"truseo_locale":null},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/develop.co.id\/training\/\" title=\"Home\">Home<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/develop.co.id\/training\/category\/engineering-technical\/\" title=\"Engineering &amp; Technical\">Engineering &amp; Technical<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/develop.co.id\/training\/category\/engineering-technical\/electrical-engineering\/\" title=\"Electrical Engineering\">Electrical Engineering<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\tBreaker-Failure Protection Relays with 50BF Functions Training\n\t\t<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"Home","link":"https:\/\/develop.co.id\/training\/"},{"label":"Engineering &amp; Technical","link":"https:\/\/develop.co.id\/training\/category\/engineering-technical\/"},{"label":"Electrical Engineering","link":"https:\/\/develop.co.id\/training\/category\/engineering-technical\/electrical-engineering\/"},{"label":"Breaker-Failure Protection Relays with 50BF Functions Training","link":"https:\/\/develop.co.id\/training\/breaker-failure-protection-relays-with-50bf-functions-training\/"}],"_links":{"self":[{"href":"https:\/\/develop.co.id\/training\/wp-json\/wp\/v2\/posts\/8402","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/develop.co.id\/training\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/develop.co.id\/training\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/develop.co.id\/training\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/develop.co.id\/training\/wp-json\/wp\/v2\/comments?post=8402"}],"version-history":[{"count":0,"href":"https:\/\/develop.co.id\/training\/wp-json\/wp\/v2\/posts\/8402\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/develop.co.id\/training\/wp-json\/wp\/v2\/media\/8629"}],"wp:attachment":[{"href":"https:\/\/develop.co.id\/training\/wp-json\/wp\/v2\/media?parent=8402"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/develop.co.id\/training\/wp-json\/wp\/v2\/categories?post=8402"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/develop.co.id\/training\/wp-json\/wp\/v2\/tags?post=8402"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}