{"id":8391,"date":"2016-04-08T03:29:40","date_gmt":"2016-04-08T03:29:40","guid":{"rendered":"https:\/\/develop.co.id\/training\/undervoltage-relays-with-27-protection-functions-training\/"},"modified":"2026-08-15T09:02:11","modified_gmt":"2026-08-15T09:02:11","slug":"undervoltage-relays-with-27-protection-functions-training","status":"publish","type":"post","link":"https:\/\/develop.co.id\/training\/undervoltage-relays-with-27-protection-functions-training\/","title":{"rendered":"Undervoltage Relays with 27 Protection Functions Training"},"content":{"rendered":"<p>DEVELOP Training Center menyelenggarakan Kelas Undervoltage Relays with 27 Protection Functions yang sangat berguna untuk mendapatkan pengetahuan tentang relay tegangan rendah fungsi 27, ambang tegangan, dropout, penundaan waktu, kondisi satu dan tiga fasa, rangkaian VT, serta pengujian trip. <br \/><\/br> Pelatihan diselenggarakan melalui pemaparan materi dan diskusi interaktif di dalam kelas. Peserta didorong untuk berpartisipasi aktif dalam memahami materi yang disampaikan oleh instruktur. <br \/><\/br> <center> <img fetchpriority=\"high\" decoding=\"async\" src=\"https:\/\/develop.co.id\/wp-content\/uploads\/2025\/09\/DV-GEN-023.jpg\" alt=\"Undervoltage Relays with 27 Protection Functions\" width=\"500\" height=\"500\"><figcaption> Undervoltage Relays with 27 Protection Functions <\/figcaption><\/center> <br \/><\/br> DEVELOP mengimplementasikan Syllabus Kelas Undervoltage Relays with 27 Protection Functions dengan tahap pembelajaran berkualitas sebagai berikut:<\/p>\n<blockquote><p><b>Sesi 1-2<\/b><\/p>\n<ul>\n<li>Undervoltage conditions in electrical power systems<\/li>\n<li>ANSI 27 voltage protection characteristics<\/li>\n<li>Phase voltage measurement and relay input requirements<\/li>\n<li>Undervoltage pickup and dropout settings<\/li>\n<li>Time delay characteristics for voltage protection<\/li>\n<li>Single-phase and three-phase voltage conditions<\/li>\n<li>Voltage transformer circuits and measurement accuracy<\/li>\n<li>Trip logic, alarms, and load circuit interfaces<\/li>\n<li>Case Study<\/li>\n<\/ul>\n<p> <b>Sesi 3-4<\/b><\/p>\n<ul>\n<li>27 relay configuration and threshold verification<\/li>\n<li>Secondary voltage injection testing<\/li>\n<li>Pickup and dropout voltage testing<\/li>\n<li>Operating-time and delay verification<\/li>\n<li>Phase voltage loss response testing<\/li>\n<li>Trip output and circuit verification<\/li>\n<li>Relay response assessment and setting refinement<\/li>\n<li>Case Study<\/li>\n<\/ul>\n<\/blockquote>\n<p><\/br> Sejalan dengan teori yang disampaikan, akan disertakan sebanyak mungkin studi kasus yang relevan dengan kondisi industri saat ini. Peserta juga diberikan kesempatan untuk bertanya dan berdiskusi terkait topik yang dibahas. <br \/><\/br> <center> <img decoding=\"async\" src=\"https:\/\/develop.co.id\/wp-content\/uploads\/2025\/09\/DV-TESTIMONIAL-008.jpg\" alt=\"Undervoltage Relays with 27 Protection Functions\" width=\"500\" height=\"500\"><figcaption> Undervoltage Relays with 27 Protection Functions <\/figcaption><\/center> <br \/><\/br> Materi Training dirancang khusus oleh para praktisi dan tenaga ahli yang kompeten serta telah berpengalaman sesuai dengan experience dan solid knowledge  mereka. Anda akan mendapat sharing ilmu langsung dari para praktisi yang berpengalaman bertahun-tahun. <br \/><\/br> Selama training, instruktur kami akan menggunakan kombinasi teori serta praktek langsung dengan studi kasus telah dipersiapkan yang menyerupai Proyek nyata. <br \/><\/br> \n<div class=\"wpcf7 no-js\" id=\"wpcf7-f4427-o1\" lang=\"en-US\" dir=\"ltr\" data-wpcf7-id=\"4427\">\n<div class=\"screen-reader-response\"><p role=\"status\" aria-live=\"polite\" aria-atomic=\"true\"><\/p> <ul><\/ul><\/div>\n<form action=\"\/training\/wp-json\/wp\/v2\/posts\/8391#wpcf7-f4427-o1\" method=\"post\" class=\"wpcf7-form init\" aria-label=\"Contact form\" novalidate=\"novalidate\" data-status=\"init\">\n<fieldset class=\"hidden-fields-container\"><input type=\"hidden\" name=\"_wpcf7\" value=\"4427\" \/><input type=\"hidden\" name=\"_wpcf7_version\" value=\"6.2.5\" \/><input type=\"hidden\" name=\"_wpcf7_locale\" value=\"en_US\" \/><input type=\"hidden\" name=\"_wpcf7_unit_tag\" value=\"wpcf7-f4427-o1\" \/><input type=\"hidden\" name=\"_wpcf7_container_post\" value=\"0\" \/><input type=\"hidden\" name=\"_wpcf7_posted_data_hash\" value=\"\" \/>\n<\/fieldset>\n<blockquote>\n\t<p><b>QUICK REGISTRATION &#10004;<\/b>\n\t<\/p>\n<\/blockquote>\n<div class=\"c-input-group\">\n\t<p><span class=\"wpcf7-form-control-wrap\" data-name=\"your-name\"><input size=\"40\" maxlength=\"400\" class=\"wpcf7-form-control wpcf7-text wpcf7-validates-as-required\" aria-required=\"true\" aria-invalid=\"false\" placeholder=\"Full name\" value=\"\" type=\"text\" name=\"your-name\" \/><\/span><br \/>\n<span class=\"wpcf7-form-control-wrap\" data-name=\"your-email\"><input size=\"40\" maxlength=\"400\" class=\"wpcf7-form-control wpcf7-email wpcf7-validates-as-required wpcf7-text wpcf7-validates-as-email\" aria-required=\"true\" aria-invalid=\"false\" placeholder=\"Email\" value=\"\" type=\"email\" name=\"your-email\" \/><\/span><br \/>\n<span class=\"wpcf7-form-control-wrap\" data-name=\"tel-428\"><input size=\"40\" maxlength=\"400\" class=\"wpcf7-form-control wpcf7-tel wpcf7-validates-as-required wpcf7-text wpcf7-validates-as-tel\" aria-required=\"true\" aria-invalid=\"false\" placeholder=\"Phone\" value=\"\" type=\"tel\" name=\"tel-428\" \/><\/span>\n\t<\/p>\n\t<p><span class=\"wpcf7-form-control-wrap\" data-name=\"your-message\"><textarea cols=\"10\" rows=\"10\" maxlength=\"2000\" class=\"wpcf7-form-control wpcf7-textarea\" aria-invalid=\"false\" placeholder=\"Special message\" name=\"your-message\"><\/textarea><\/span>\n\t<\/p>\n\t<p><span id=\"wpcf7-6b0352668ed51-wrapper\" class=\"wpcf7-form-control-wrap cf7apps-honeypot-wrap honeypot-469-wrap\" data-cf7apps-honeypot=\"honeypot-469\" style=\"position:absolute;width:1px;height:1px;padding:0;margin:-1px;overflow:hidden;clip:rect(0,0,0,0);white-space:nowrap;border:0;\"><input type=\"hidden\" name=\"honeypot-469-random-hash\" value=\"20261122\"><input type=\"hidden\" name=\"honeypot-469-time-token\" value=\"MTc5NTM3OTgxNA==.677140d0de4527823a4bfa0cfb126ebfe22e77f9aab1900d7144ab49a03d0efe\"><label\n\t\t    for=\"wpcf7-6b0352668ed51-field\"\n\t\t    class=\"hp-message\"\n        >Please leave this field empty.<\/label><input\n\t    id=\"wpcf7-6b0352668ed51-field\"\n\t    \n\t    class=\"wpcf7-form-control wpcf7-text\"\n\t    type=\"text\"\n\t    name=\"j7k4bslua0vo\"\n\t    value=\"\"\n\t    autocomplete=\"new-password\"\n\t    tabindex=\"1000\"\n\t    data-cf7apps-tabindex=\"1000\"\n    \/><\/span><br \/>\n<input class=\"wpcf7-form-control wpcf7-submit has-spinner\" type=\"submit\" value=\"REGISTER NOW\" \/>\n\t<\/p>\n<\/div><div class=\"wpcf7-response-output\" aria-hidden=\"true\"><\/div>\n<\/form>\n<\/div>\n<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Pelajari teknik proteksi tegangan rendah 27 untuk meningkatkan kemampuan setting ambang, pengujian tegangan, verifikasi waktu, dan evaluasi trip.<\/p>\n","protected":false},"author":1,"featured_media":8897,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_monsterinsights_skip_tracking":false,"footnotes":""},"categories":[34,38],"tags":[8519,193,8520,8525,8527,8518,8526,8522,8521,8523,8524],"class_list":["post-8391","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-electrical-engineering","category-instrument-engineering","tag-ansi-27-relay","tag-electrical-engineering","tag-low-voltage-protection","tag-phase-voltage-protection","tag-power-system-voltage-relay","tag-undervoltage-protection-relay","tag-undervoltage-relay-testing","tag-undervoltage-trip-system","tag-voltage-relay-settings","tag-voltage-threshold-testing","tag-vt-relay-protection"],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 5.0.5.1 - aioseo.com -->\n\t<meta name=\"description\" content=\"Pelajari teknik proteksi tegangan rendah 27 untuk meningkatkan kemampuan setting ambang, pengujian tegangan, verifikasi waktu, dan evaluasi trip.\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<link rel=\"canonical\" href=\"https:\/\/develop.co.id\/training\/undervoltage-relays-with-27-protection-functions-training\/\" \/>\n\t\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 5.0.5.1\" \/>\n\t\t<meta property=\"og:locale\" content=\"en_US\" \/>\n\t\t<meta property=\"og:site_name\" content=\"DEVELOP - Oil Gas,Petrochemical, Power Plant,Mining&amp;Industrial Training Specialist\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"Undervoltage Relays with 27 Protection Functions Training - DEVELOP\" \/>\n\t\t<meta property=\"og:description\" content=\"Pelajari teknik proteksi tegangan rendah 27 untuk meningkatkan kemampuan setting ambang, pengujian tegangan, verifikasi waktu, dan evaluasi trip.\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/develop.co.id\/training\/undervoltage-relays-with-27-protection-functions-training\/\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/develop.co.id\/training\/wp-content\/uploads\/2026\/07\/DEVELOP-Logo-ls4-300x150-1.png\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/develop.co.id\/training\/wp-content\/uploads\/2026\/07\/DEVELOP-Logo-ls4-300x150-1.png\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2016-04-08T03:29:40+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2026-08-15T09:02:11+00:00\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:title\" content=\"Undervoltage Relays with 27 Protection Functions Training - DEVELOP\" \/>\n\t\t<meta name=\"twitter:description\" content=\"Pelajari teknik proteksi tegangan rendah 27 untuk meningkatkan kemampuan setting ambang, pengujian tegangan, verifikasi waktu, dan evaluasi trip.\" \/>\n\t\t<meta name=\"twitter:image\" content=\"https:\/\/develop.co.id\/training\/wp-content\/uploads\/2026\/07\/DEVELOP-Logo-ls4-300x150-1.png\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"BlogPosting\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/undervoltage-relays-with-27-protection-functions-training\\\/#blogposting\",\"name\":\"Undervoltage Relays with 27 Protection Functions Training - DEVELOP\",\"headline\":\"Undervoltage Relays with 27 Protection Functions Training\",\"author\":{\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/author\\\/developtraining\\\/#author\"},\"publisher\":{\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/#organization\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/develop.co.id\\\/training\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/undervoltage-relays-with-27-protection-functions-training_8391_dafe9.png\",\"width\":800,\"height\":600},\"datePublished\":\"2016-04-08T03:29:40+00:00\",\"dateModified\":\"2026-08-15T09:02:11+00:00\",\"inLanguage\":\"en-US\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/undervoltage-relays-with-27-protection-functions-training\\\/#webpage\"},\"isPartOf\":{\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/undervoltage-relays-with-27-protection-functions-training\\\/#webpage\"},\"articleSection\":\"Electrical Engineering, Instrument Engineering, ANSI 27 relay, Electrical Engineering, low voltage protection, phase voltage protection, power system voltage relay, undervoltage protection relay, undervoltage relay testing, undervoltage trip system, voltage relay settings, voltage threshold testing, VT relay protection\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/undervoltage-relays-with-27-protection-functions-training\\\/#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/#listItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/develop.co.id\\\/training\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/category\\\/engineering-technical\\\/#listItem\",\"name\":\"Engineering &amp; Technical\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/category\\\/engineering-technical\\\/#listItem\",\"position\":2,\"name\":\"Engineering &amp; Technical\",\"item\":\"https:\\\/\\\/develop.co.id\\\/training\\\/category\\\/engineering-technical\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/category\\\/engineering-technical\\\/electrical-engineering\\\/#listItem\",\"name\":\"Electrical Engineering\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/#listItem\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/category\\\/engineering-technical\\\/electrical-engineering\\\/#listItem\",\"position\":3,\"name\":\"Electrical Engineering\",\"item\":\"https:\\\/\\\/develop.co.id\\\/training\\\/category\\\/engineering-technical\\\/electrical-engineering\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/undervoltage-relays-with-27-protection-functions-training\\\/#listItem\",\"name\":\"Undervoltage Relays with 27 Protection Functions Training\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/category\\\/engineering-technical\\\/#listItem\",\"name\":\"Engineering &amp; Technical\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/undervoltage-relays-with-27-protection-functions-training\\\/#listItem\",\"position\":4,\"name\":\"Undervoltage Relays with 27 Protection Functions Training\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/category\\\/engineering-technical\\\/electrical-engineering\\\/#listItem\",\"name\":\"Electrical Engineering\"}}]},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/#organization\",\"name\":\"DEVELOP\",\"description\":\"Oil Gas,Petrochemical, Power Plant,Mining&Industrial Training Specialist\",\"url\":\"https:\\\/\\\/develop.co.id\\\/training\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/develop.co.id\\\/training\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/DEVELOP-Logo-ls4-300x150-1.png\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/undervoltage-relays-with-27-protection-functions-training\\\/#organizationLogo\",\"width\":300,\"height\":150},\"image\":{\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/undervoltage-relays-with-27-protection-functions-training\\\/#organizationLogo\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/author\\\/developtraining\\\/#author\",\"url\":\"https:\\\/\\\/develop.co.id\\\/training\\\/author\\\/developtraining\\\/\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/undervoltage-relays-with-27-protection-functions-training\\\/#authorImage\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/6b88ccabac9c627e76fb131519cdc3ef0e725eb1ff178c0eaa169a92fc8becc5?s=96&d=mm&r=g\",\"width\":96,\"height\":96}},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/undervoltage-relays-with-27-protection-functions-training\\\/#webpage\",\"url\":\"https:\\\/\\\/develop.co.id\\\/training\\\/undervoltage-relays-with-27-protection-functions-training\\\/\",\"name\":\"Undervoltage Relays with 27 Protection Functions Training - DEVELOP\",\"description\":\"Pelajari teknik proteksi tegangan rendah 27 untuk meningkatkan kemampuan setting ambang, pengujian tegangan, verifikasi waktu, dan evaluasi trip.\",\"inLanguage\":\"en-US\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/undervoltage-relays-with-27-protection-functions-training\\\/#breadcrumblist\"},\"author\":{\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/author\\\/developtraining\\\/#author\"},\"creator\":{\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/author\\\/developtraining\\\/#author\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/develop.co.id\\\/training\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/undervoltage-relays-with-27-protection-functions-training_8391_dafe9.png\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/undervoltage-relays-with-27-protection-functions-training\\\/#mainImage\",\"width\":800,\"height\":600},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/undervoltage-relays-with-27-protection-functions-training\\\/#mainImage\"},\"datePublished\":\"2016-04-08T03:29:40+00:00\",\"dateModified\":\"2026-08-15T09:02:11+00:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/#website\",\"url\":\"https:\\\/\\\/develop.co.id\\\/training\\\/\",\"name\":\"DEVELOP\",\"description\":\"Oil Gas,Petrochemical, Power Plant,Mining&Industrial Training Specialist\",\"inLanguage\":\"en-US\",\"publisher\":{\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/#organization\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"Undervoltage Relays with 27 Protection Functions Training - DEVELOP","description":"Pelajari teknik proteksi tegangan rendah 27 untuk meningkatkan kemampuan setting ambang, pengujian tegangan, verifikasi waktu, dan evaluasi trip.","canonical_url":"https:\/\/develop.co.id\/training\/undervoltage-relays-with-27-protection-functions-training\/","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"BlogPosting","@id":"https:\/\/develop.co.id\/training\/undervoltage-relays-with-27-protection-functions-training\/#blogposting","name":"Undervoltage Relays with 27 Protection Functions Training - DEVELOP","headline":"Undervoltage Relays with 27 Protection Functions Training","author":{"@id":"https:\/\/develop.co.id\/training\/author\/developtraining\/#author"},"publisher":{"@id":"https:\/\/develop.co.id\/training\/#organization"},"image":{"@type":"ImageObject","url":"https:\/\/develop.co.id\/training\/wp-content\/uploads\/2026\/08\/undervoltage-relays-with-27-protection-functions-training_8391_dafe9.png","width":800,"height":600},"datePublished":"2016-04-08T03:29:40+00:00","dateModified":"2026-08-15T09:02:11+00:00","inLanguage":"en-US","mainEntityOfPage":{"@id":"https:\/\/develop.co.id\/training\/undervoltage-relays-with-27-protection-functions-training\/#webpage"},"isPartOf":{"@id":"https:\/\/develop.co.id\/training\/undervoltage-relays-with-27-protection-functions-training\/#webpage"},"articleSection":"Electrical Engineering, Instrument Engineering, ANSI 27 relay, Electrical Engineering, low voltage protection, phase voltage protection, power system voltage relay, undervoltage protection relay, undervoltage relay testing, undervoltage trip system, voltage relay settings, voltage threshold testing, VT relay protection"},{"@type":"BreadcrumbList","@id":"https:\/\/develop.co.id\/training\/undervoltage-relays-with-27-protection-functions-training\/#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/develop.co.id\/training\/#listItem","position":1,"name":"Home","item":"https:\/\/develop.co.id\/training\/","nextItem":{"@type":"ListItem","@id":"https:\/\/develop.co.id\/training\/category\/engineering-technical\/#listItem","name":"Engineering &amp; Technical"}},{"@type":"ListItem","@id":"https:\/\/develop.co.id\/training\/category\/engineering-technical\/#listItem","position":2,"name":"Engineering &amp; Technical","item":"https:\/\/develop.co.id\/training\/category\/engineering-technical\/","nextItem":{"@type":"ListItem","@id":"https:\/\/develop.co.id\/training\/category\/engineering-technical\/electrical-engineering\/#listItem","name":"Electrical Engineering"},"previousItem":{"@type":"ListItem","@id":"https:\/\/develop.co.id\/training\/#listItem","name":"Home"}},{"@type":"ListItem","@id":"https:\/\/develop.co.id\/training\/category\/engineering-technical\/electrical-engineering\/#listItem","position":3,"name":"Electrical Engineering","item":"https:\/\/develop.co.id\/training\/category\/engineering-technical\/electrical-engineering\/","nextItem":{"@type":"ListItem","@id":"https:\/\/develop.co.id\/training\/undervoltage-relays-with-27-protection-functions-training\/#listItem","name":"Undervoltage Relays with 27 Protection Functions Training"},"previousItem":{"@type":"ListItem","@id":"https:\/\/develop.co.id\/training\/category\/engineering-technical\/#listItem","name":"Engineering &amp; Technical"}},{"@type":"ListItem","@id":"https:\/\/develop.co.id\/training\/undervoltage-relays-with-27-protection-functions-training\/#listItem","position":4,"name":"Undervoltage Relays with 27 Protection Functions Training","previousItem":{"@type":"ListItem","@id":"https:\/\/develop.co.id\/training\/category\/engineering-technical\/electrical-engineering\/#listItem","name":"Electrical Engineering"}}]},{"@type":"Organization","@id":"https:\/\/develop.co.id\/training\/#organization","name":"DEVELOP","description":"Oil Gas,Petrochemical, Power Plant,Mining&Industrial Training Specialist","url":"https:\/\/develop.co.id\/training\/","logo":{"@type":"ImageObject","url":"https:\/\/develop.co.id\/training\/wp-content\/uploads\/2026\/07\/DEVELOP-Logo-ls4-300x150-1.png","@id":"https:\/\/develop.co.id\/training\/undervoltage-relays-with-27-protection-functions-training\/#organizationLogo","width":300,"height":150},"image":{"@id":"https:\/\/develop.co.id\/training\/undervoltage-relays-with-27-protection-functions-training\/#organizationLogo"}},{"@type":"Person","@id":"https:\/\/develop.co.id\/training\/author\/developtraining\/#author","url":"https:\/\/develop.co.id\/training\/author\/developtraining\/","image":{"@type":"ImageObject","@id":"https:\/\/develop.co.id\/training\/undervoltage-relays-with-27-protection-functions-training\/#authorImage","url":"https:\/\/secure.gravatar.com\/avatar\/6b88ccabac9c627e76fb131519cdc3ef0e725eb1ff178c0eaa169a92fc8becc5?s=96&d=mm&r=g","width":96,"height":96}},{"@type":"WebPage","@id":"https:\/\/develop.co.id\/training\/undervoltage-relays-with-27-protection-functions-training\/#webpage","url":"https:\/\/develop.co.id\/training\/undervoltage-relays-with-27-protection-functions-training\/","name":"Undervoltage Relays with 27 Protection Functions Training - DEVELOP","description":"Pelajari teknik proteksi tegangan rendah 27 untuk meningkatkan kemampuan setting ambang, pengujian tegangan, verifikasi waktu, dan evaluasi trip.","inLanguage":"en-US","isPartOf":{"@id":"https:\/\/develop.co.id\/training\/#website"},"breadcrumb":{"@id":"https:\/\/develop.co.id\/training\/undervoltage-relays-with-27-protection-functions-training\/#breadcrumblist"},"author":{"@id":"https:\/\/develop.co.id\/training\/author\/developtraining\/#author"},"creator":{"@id":"https:\/\/develop.co.id\/training\/author\/developtraining\/#author"},"image":{"@type":"ImageObject","url":"https:\/\/develop.co.id\/training\/wp-content\/uploads\/2026\/08\/undervoltage-relays-with-27-protection-functions-training_8391_dafe9.png","@id":"https:\/\/develop.co.id\/training\/undervoltage-relays-with-27-protection-functions-training\/#mainImage","width":800,"height":600},"primaryImageOfPage":{"@id":"https:\/\/develop.co.id\/training\/undervoltage-relays-with-27-protection-functions-training\/#mainImage"},"datePublished":"2016-04-08T03:29:40+00:00","dateModified":"2026-08-15T09:02:11+00:00"},{"@type":"WebSite","@id":"https:\/\/develop.co.id\/training\/#website","url":"https:\/\/develop.co.id\/training\/","name":"DEVELOP","description":"Oil Gas,Petrochemical, Power Plant,Mining&Industrial Training Specialist","inLanguage":"en-US","publisher":{"@id":"https:\/\/develop.co.id\/training\/#organization"}}]},"og:locale":"en_US","og:site_name":"DEVELOP - Oil Gas,Petrochemical, Power Plant,Mining&amp;Industrial Training Specialist","og:type":"article","og:title":"Undervoltage Relays with 27 Protection Functions Training - DEVELOP","og:description":"Pelajari teknik proteksi tegangan rendah 27 untuk meningkatkan kemampuan setting ambang, pengujian tegangan, verifikasi waktu, dan evaluasi trip.","og:url":"https:\/\/develop.co.id\/training\/undervoltage-relays-with-27-protection-functions-training\/","og:image":"https:\/\/develop.co.id\/training\/wp-content\/uploads\/2026\/07\/DEVELOP-Logo-ls4-300x150-1.png","og:image:secure_url":"https:\/\/develop.co.id\/training\/wp-content\/uploads\/2026\/07\/DEVELOP-Logo-ls4-300x150-1.png","article:published_time":"2016-04-08T03:29:40+00:00","article:modified_time":"2026-08-15T09:02:11+00:00","twitter:card":"summary_large_image","twitter:title":"Undervoltage Relays with 27 Protection Functions Training - DEVELOP","twitter:description":"Pelajari teknik proteksi tegangan rendah 27 untuk meningkatkan kemampuan setting ambang, pengujian tegangan, verifikasi waktu, dan evaluasi trip.","twitter:image":"https:\/\/develop.co.id\/training\/wp-content\/uploads\/2026\/07\/DEVELOP-Logo-ls4-300x150-1.png"},"aioseo_meta_data":{"post_id":"8391","title":null,"description":null,"keywords":null,"keyphrases":null,"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_custom_url":null,"og_image_custom_fields":null,"og_image_url":null,"og_image_width":null,"og_image_height":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":true,"twitter_card":"default","twitter_image_type":"default","twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_image_url":null,"twitter_title":null,"twitter_description":null,"schema_type":"default","schema_type_options":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"","isEnabled":true},"graphs":[]},"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"limit_modified_date":false,"ai":null,"breadcrumb_settings":null,"seo_analyzer_scan_date":null,"created":"2026-08-15 09:01:08","updated":"2026-08-15 09:07:54","focus_keyword":null,"additional_keywords":null,"truseo_locale":null},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/develop.co.id\/training\/\" title=\"Home\">Home<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/develop.co.id\/training\/category\/engineering-technical\/\" title=\"Engineering &amp; Technical\">Engineering &amp; Technical<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/develop.co.id\/training\/category\/engineering-technical\/electrical-engineering\/\" title=\"Electrical Engineering\">Electrical Engineering<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\tUndervoltage Relays with 27 Protection Functions Training\n\t\t<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"Home","link":"https:\/\/develop.co.id\/training\/"},{"label":"Engineering &amp; Technical","link":"https:\/\/develop.co.id\/training\/category\/engineering-technical\/"},{"label":"Electrical Engineering","link":"https:\/\/develop.co.id\/training\/category\/engineering-technical\/electrical-engineering\/"},{"label":"Undervoltage Relays with 27 Protection Functions Training","link":"https:\/\/develop.co.id\/training\/undervoltage-relays-with-27-protection-functions-training\/"}],"_links":{"self":[{"href":"https:\/\/develop.co.id\/training\/wp-json\/wp\/v2\/posts\/8391","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/develop.co.id\/training\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/develop.co.id\/training\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/develop.co.id\/training\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/develop.co.id\/training\/wp-json\/wp\/v2\/comments?post=8391"}],"version-history":[{"count":0,"href":"https:\/\/develop.co.id\/training\/wp-json\/wp\/v2\/posts\/8391\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/develop.co.id\/training\/wp-json\/wp\/v2\/media\/8897"}],"wp:attachment":[{"href":"https:\/\/develop.co.id\/training\/wp-json\/wp\/v2\/media?parent=8391"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/develop.co.id\/training\/wp-json\/wp\/v2\/categories?post=8391"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/develop.co.id\/training\/wp-json\/wp\/v2\/tags?post=8391"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}