{"id":10760,"date":"2026-08-30T15:28:33","date_gmt":"2026-08-30T15:28:33","guid":{"rendered":"https:\/\/develop.co.id\/training\/motor-current-measurement-and-protection-circuit-verification-training\/"},"modified":"2026-09-11T05:40:04","modified_gmt":"2026-09-11T05:40:04","slug":"motor-current-measurement-and-protection-circuit-verification-training","status":"publish","type":"post","link":"https:\/\/develop.co.id\/training\/motor-current-measurement-and-protection-circuit-verification-training\/","title":{"rendered":"Motor Current Measurement and Protection Circuit Verification Training"},"content":{"rendered":"<p>DEVELOP Training Center menyelenggarakan Kelas Motor Current Measurement and Protection Circuit Verification yang sangat berguna untuk mendapatkan pengetahuan tentang pengukuran arus motor dan verifikasi rangkaian proteksi, pemeriksaan keseimbangan arus, pengujian CT, input relay, alarm, trip, serta identifikasi kondisi arus abnormal pada feeder motor. <br \/><\/br> Pelatihan dilaksanakan melalui pemaparan materi dan diskusi interaktif di dalam kelas. Peserta pelatihan didorong untuk berperan aktif dalam memahami materi yang disampaikan oleh instruktur. <br \/><\/br> <center> <img fetchpriority=\"high\" decoding=\"async\" class=\"aligncenter size-full wp-image-6398\" src=\"https:\/\/develop.co.id\/wp-content\/uploads\/2025\/07\/DV-GEN-039.jpg\" alt=\"Motor Current Measurement and Protection Circuit Verification\" width=\"300\" height=\"300\"><figcaption> Motor Current Measurement and Protection Circuit Verification <\/figcaption><\/center> <br \/><\/br> DEVELOP mengimplementasikan Syllabus Kelas Motor Current Measurement and Protection Circuit Verification Training dengan tahap pembelajaran berkualitas sebagai berikut:<\/p>\n<blockquote><p><b>Sesi 1-2<\/b><\/p>\n<ul>\n<li>Motor current measurement system architecture<\/li>\n<li>Three-phase motor current characteristics<\/li>\n<li>Current transformer construction and applications<\/li>\n<li>CT ratio, polarity, and secondary circuit connections<\/li>\n<li>Motor feeder protection circuit arrangements<\/li>\n<li>Overload and short-circuit protection interfaces<\/li>\n<li>Current sensing devices and measurement connections<\/li>\n<li>Motor starter current monitoring circuits<\/li>\n<li>Protection relay current input circuits<\/li>\n<li>Current alarm and trip signal arrangements<\/li>\n<li>Pre-test inspection of current measurement circuits<\/li>\n<li>Case Study<\/li>\n<\/ul>\n<p><b>Sesi 3-4<\/b><\/p>\n<ul>\n<li>Phase current measurement and comparison<\/li>\n<li>Current imbalance measurement and assessment<\/li>\n<li>CT secondary current verification<\/li>\n<li>CT polarity and ratio testing<\/li>\n<li>Protection relay current input verification<\/li>\n<li>Overload trip current testing<\/li>\n<li>Current alarm threshold verification<\/li>\n<li>Motor feeder trip circuit testing<\/li>\n<li>Current measurement instrument verification<\/li>\n<li>Abnormal current condition identification<\/li>\n<li>Protection circuit response assessment<\/li>\n<li>Measurement records and verification documentation<\/li>\n<li>Case Study<\/li>\n<\/ul>\n<\/blockquote>\n<p><\/br> Sejalan dengan teori yang disampaikan, sebanyak mungkin akan disertakan contoh-contoh studi kasus yang relevan dengan kondisi industri saat ini. Peserta juga diberikan kesempatan untuk mengajukan pertanyaan dan mendiskusikan topik-topik yang dibahas. <br \/><\/br> <center> <img decoding=\"async\" class=\"aligncenter size-full wp-image-23814\" src=\"https:\/\/develop.co.id\/wp-content\/uploads\/2025\/07\/DV-TESTIMONIAL-030.jpg\" alt=\"Motor Current Measurement and Protection Circuit Verification\" width=\"400\" height=\"400\"><figcaption> Motor Current Measurement and Protection Circuit Verification <\/figcaption><\/center> <br \/><\/br> Materi Training dirancang khusus oleh para praktisi dan tenaga ahli yang kompeten serta telah berpengalaman sesuai dengan experience dan solid knowledge  mereka. Anda akan mendapat sharing ilmu langsung dari para praktisi yang berpengalaman bertahun-tahun. <br \/><\/br> Selama training, instruktur kami akan menggunakan kombinasi teori serta praktek langsung dengan studi kasus telah dipersiapkan yang menyerupai Proyek nyata. <br \/><\/br> \n<div class=\"wpcf7 no-js\" id=\"wpcf7-f4427-o1\" lang=\"en-US\" dir=\"ltr\" data-wpcf7-id=\"4427\">\n<div class=\"screen-reader-response\"><p role=\"status\" aria-live=\"polite\" aria-atomic=\"true\"><\/p> <ul><\/ul><\/div>\n<form action=\"\/training\/wp-json\/wp\/v2\/posts\/10760#wpcf7-f4427-o1\" method=\"post\" class=\"wpcf7-form init\" aria-label=\"Contact form\" novalidate=\"novalidate\" data-status=\"init\">\n<fieldset class=\"hidden-fields-container\"><input type=\"hidden\" name=\"_wpcf7\" value=\"4427\" \/><input type=\"hidden\" name=\"_wpcf7_version\" value=\"6.2.5\" \/><input type=\"hidden\" name=\"_wpcf7_locale\" value=\"en_US\" \/><input type=\"hidden\" name=\"_wpcf7_unit_tag\" value=\"wpcf7-f4427-o1\" \/><input type=\"hidden\" name=\"_wpcf7_container_post\" value=\"0\" \/><input type=\"hidden\" name=\"_wpcf7_posted_data_hash\" value=\"\" \/>\n<\/fieldset>\n<blockquote>\n\t<p><b>QUICK REGISTRATION &#10004;<\/b>\n\t<\/p>\n<\/blockquote>\n<div class=\"c-input-group\">\n\t<p><span class=\"wpcf7-form-control-wrap\" data-name=\"your-name\"><input size=\"40\" maxlength=\"400\" class=\"wpcf7-form-control wpcf7-text wpcf7-validates-as-required\" aria-required=\"true\" aria-invalid=\"false\" placeholder=\"Full name\" value=\"\" type=\"text\" name=\"your-name\" \/><\/span><br \/>\n<span class=\"wpcf7-form-control-wrap\" data-name=\"your-email\"><input size=\"40\" maxlength=\"400\" class=\"wpcf7-form-control wpcf7-email wpcf7-validates-as-required wpcf7-text wpcf7-validates-as-email\" aria-required=\"true\" aria-invalid=\"false\" placeholder=\"Email\" value=\"\" type=\"email\" name=\"your-email\" \/><\/span><br \/>\n<span class=\"wpcf7-form-control-wrap\" data-name=\"tel-428\"><input size=\"40\" maxlength=\"400\" class=\"wpcf7-form-control wpcf7-tel wpcf7-validates-as-required wpcf7-text wpcf7-validates-as-tel\" aria-required=\"true\" aria-invalid=\"false\" placeholder=\"Phone\" value=\"\" type=\"tel\" name=\"tel-428\" \/><\/span>\n\t<\/p>\n\t<p><span class=\"wpcf7-form-control-wrap\" data-name=\"your-message\"><textarea cols=\"10\" rows=\"10\" maxlength=\"2000\" class=\"wpcf7-form-control wpcf7-textarea\" aria-invalid=\"false\" placeholder=\"Special message\" name=\"your-message\"><\/textarea><\/span>\n\t<\/p>\n\t<p><input class=\"wpcf7-form-control wpcf7-submit has-spinner\" type=\"submit\" value=\"REGISTER NOW\" \/>\n\t<\/p>\n<\/div><div class=\"wpcf7-response-output\" aria-hidden=\"true\"><\/div>\n<\/form>\n<\/div>\n<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Tingkatkan kemampuan profesional dalam pengukuran arus motor dan verifikasi proteksi untuk menemukan ketidakseimbangan, memeriksa CT, serta memastikan fungsi trip.<\/p>\n","protected":false},"author":1,"featured_media":11333,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"om_disable_all_campaigns":false,"_monsterinsights_skip_tracking":false,"footnotes":""},"categories":[37,38],"tags":[2499],"class_list":["post-10760","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-industrial-engineering","category-instrument-engineering","tag-instrument-engineering"],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 5.0.5.1 - aioseo.com -->\n\t<meta name=\"description\" content=\"Tingkatkan kemampuan profesional dalam pengukuran arus motor dan verifikasi proteksi untuk menemukan ketidakseimbangan, memeriksa CT, serta memastikan fungsi trip.\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<link rel=\"canonical\" href=\"https:\/\/develop.co.id\/training\/motor-current-measurement-and-protection-circuit-verification-training\/\" \/>\n\t\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 5.0.5.1\" \/>\n\t\t<meta property=\"og:locale\" content=\"en_US\" \/>\n\t\t<meta property=\"og:site_name\" content=\"DEVELOP - Oil Gas,Petrochemical, Power Plant,Mining&amp;Industrial Training Specialist\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"Motor Current Measurement and Protection Circuit Verification Training - DEVELOP\" \/>\n\t\t<meta property=\"og:description\" content=\"Tingkatkan kemampuan profesional dalam pengukuran arus motor dan verifikasi proteksi untuk menemukan ketidakseimbangan, memeriksa CT, serta memastikan fungsi trip.\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/develop.co.id\/training\/motor-current-measurement-and-protection-circuit-verification-training\/\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/develop.co.id\/training\/wp-content\/uploads\/2026\/11\/develop-co-id-32-light-blue-300px.jpg\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/develop.co.id\/training\/wp-content\/uploads\/2026\/11\/develop-co-id-32-light-blue-300px.jpg\" \/>\n\t\t<meta property=\"og:image:width\" content=\"300\" \/>\n\t\t<meta property=\"og:image:height\" content=\"300\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2026-08-30T15:28:33+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2026-09-11T05:40:04+00:00\" \/>\n\t\t<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/sertifikasikerja\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:site\" content=\"@oilgascourse\" \/>\n\t\t<meta name=\"twitter:title\" content=\"Motor Current Measurement and Protection Circuit Verification Training - DEVELOP\" \/>\n\t\t<meta name=\"twitter:description\" content=\"Tingkatkan kemampuan profesional dalam pengukuran arus motor dan verifikasi proteksi untuk menemukan ketidakseimbangan, memeriksa CT, serta memastikan fungsi trip.\" \/>\n\t\t<meta name=\"twitter:creator\" content=\"@oilgascourse\" \/>\n\t\t<meta name=\"twitter:image\" content=\"https:\/\/develop.co.id\/training\/wp-content\/uploads\/2026\/11\/develop-co-id-32-light-blue-300px.jpg\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"BlogPosting\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/motor-current-measurement-and-protection-circuit-verification-training\\\/#blogposting\",\"name\":\"Motor Current Measurement and Protection Circuit Verification Training - DEVELOP\",\"headline\":\"Motor Current Measurement and Protection Circuit Verification Training\",\"author\":{\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/author\\\/developtraining\\\/#author\"},\"publisher\":{\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/#organization\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/develop.co.id\\\/training\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/motor-current-measurement-and-protection-circuit-verification-training_10760_2de0b.png\",\"width\":800,\"height\":600},\"datePublished\":\"2026-08-30T15:28:33+00:00\",\"dateModified\":\"2026-09-11T05:40:04+00:00\",\"inLanguage\":\"en-US\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/motor-current-measurement-and-protection-circuit-verification-training\\\/#webpage\"},\"isPartOf\":{\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/motor-current-measurement-and-protection-circuit-verification-training\\\/#webpage\"},\"articleSection\":\"Industrial Engineering, Instrument Engineering, Instrument Engineering\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/motor-current-measurement-and-protection-circuit-verification-training\\\/#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/#listItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/develop.co.id\\\/training\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/category\\\/engineering-technical\\\/#listItem\",\"name\":\"Engineering &amp; Technical\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/category\\\/engineering-technical\\\/#listItem\",\"position\":2,\"name\":\"Engineering &amp; Technical\",\"item\":\"https:\\\/\\\/develop.co.id\\\/training\\\/category\\\/engineering-technical\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/category\\\/engineering-technical\\\/industrial-engineering\\\/#listItem\",\"name\":\"Industrial Engineering\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/#listItem\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/category\\\/engineering-technical\\\/industrial-engineering\\\/#listItem\",\"position\":3,\"name\":\"Industrial Engineering\",\"item\":\"https:\\\/\\\/develop.co.id\\\/training\\\/category\\\/engineering-technical\\\/industrial-engineering\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/motor-current-measurement-and-protection-circuit-verification-training\\\/#listItem\",\"name\":\"Motor Current Measurement and Protection Circuit Verification Training\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/category\\\/engineering-technical\\\/#listItem\",\"name\":\"Engineering &amp; Technical\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/motor-current-measurement-and-protection-circuit-verification-training\\\/#listItem\",\"position\":4,\"name\":\"Motor Current Measurement and Protection Circuit Verification Training\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/category\\\/engineering-technical\\\/industrial-engineering\\\/#listItem\",\"name\":\"Industrial Engineering\"}}]},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/#organization\",\"name\":\"DEVELOP\",\"description\":\"Oil Gas,Petrochemical, Power Plant,Mining&Industrial Training Specialist\",\"url\":\"https:\\\/\\\/develop.co.id\\\/training\\\/\",\"telephone\":\"+628159147070\",\"logo\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/develop.co.id\\\/training\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/develop-co-id-32-light-blue-300px.jpg\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/motor-current-measurement-and-protection-circuit-verification-training\\\/#organizationLogo\",\"width\":300,\"height\":300},\"image\":{\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/motor-current-measurement-and-protection-circuit-verification-training\\\/#organizationLogo\"},\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/sertifikasikerja\",\"https:\\\/\\\/x.com\\\/oilgascourse\",\"https:\\\/\\\/www.instagram.com\\\/developtrainingofficial\",\"https:\\\/\\\/tiktok.com\\\/@develop.course\",\"https:\\\/\\\/www.linkedin.com\\\/company\\\/develop-course\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/author\\\/developtraining\\\/#author\",\"url\":\"https:\\\/\\\/develop.co.id\\\/training\\\/author\\\/developtraining\\\/\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/motor-current-measurement-and-protection-circuit-verification-training\\\/#authorImage\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/6b88ccabac9c627e76fb131519cdc3ef0e725eb1ff178c0eaa169a92fc8becc5?s=96&d=mm&r=g\",\"width\":96,\"height\":96}},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/motor-current-measurement-and-protection-circuit-verification-training\\\/#webpage\",\"url\":\"https:\\\/\\\/develop.co.id\\\/training\\\/motor-current-measurement-and-protection-circuit-verification-training\\\/\",\"name\":\"Motor Current Measurement and Protection Circuit Verification Training - DEVELOP\",\"description\":\"Tingkatkan kemampuan profesional dalam pengukuran arus motor dan verifikasi proteksi untuk menemukan ketidakseimbangan, memeriksa CT, serta memastikan fungsi trip.\",\"inLanguage\":\"en-US\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/motor-current-measurement-and-protection-circuit-verification-training\\\/#breadcrumblist\"},\"author\":{\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/author\\\/developtraining\\\/#author\"},\"creator\":{\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/author\\\/developtraining\\\/#author\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/develop.co.id\\\/training\\\/wp-content\\\/uploads\\\/2026\\\/09\\\/motor-current-measurement-and-protection-circuit-verification-training_10760_2de0b.png\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/motor-current-measurement-and-protection-circuit-verification-training\\\/#mainImage\",\"width\":800,\"height\":600},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/motor-current-measurement-and-protection-circuit-verification-training\\\/#mainImage\"},\"datePublished\":\"2026-08-30T15:28:33+00:00\",\"dateModified\":\"2026-09-11T05:40:04+00:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/#website\",\"url\":\"https:\\\/\\\/develop.co.id\\\/training\\\/\",\"name\":\"DEVELOP\",\"description\":\"Oil Gas,Petrochemical, Power Plant,Mining&Industrial Training Specialist\",\"inLanguage\":\"en-US\",\"publisher\":{\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/#organization\"}}]}\n\t\t<\/script>\n\t\t<script type=\"text\/javascript\">\n\t\t\t(function(c,l,a,r,i,t,y){\n\t\t\tc[a]=c[a]||function(){(c[a].q=c[a].q||[]).push(arguments)};t=l.createElement(r);t.async=1;\n\t\t\tt.src=\"https:\/\/www.clarity.ms\/tag\/\"+i+\"?ref=aioseo\";y=l.getElementsByTagName(r)[0];y.parentNode.insertBefore(t,y);\n\t\t})(window, document, \"clarity\", \"script\", \"zdv8xzjv86\");\n\t\t<\/script>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"Motor Current Measurement and Protection Circuit Verification Training - DEVELOP","description":"Tingkatkan kemampuan profesional dalam pengukuran arus motor dan verifikasi proteksi untuk menemukan ketidakseimbangan, memeriksa CT, serta memastikan fungsi trip.","canonical_url":"https:\/\/develop.co.id\/training\/motor-current-measurement-and-protection-circuit-verification-training\/","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"BlogPosting","@id":"https:\/\/develop.co.id\/training\/motor-current-measurement-and-protection-circuit-verification-training\/#blogposting","name":"Motor Current Measurement and Protection Circuit Verification Training - DEVELOP","headline":"Motor Current Measurement and Protection Circuit Verification Training","author":{"@id":"https:\/\/develop.co.id\/training\/author\/developtraining\/#author"},"publisher":{"@id":"https:\/\/develop.co.id\/training\/#organization"},"image":{"@type":"ImageObject","url":"https:\/\/develop.co.id\/training\/wp-content\/uploads\/2026\/09\/motor-current-measurement-and-protection-circuit-verification-training_10760_2de0b.png","width":800,"height":600},"datePublished":"2026-08-30T15:28:33+00:00","dateModified":"2026-09-11T05:40:04+00:00","inLanguage":"en-US","mainEntityOfPage":{"@id":"https:\/\/develop.co.id\/training\/motor-current-measurement-and-protection-circuit-verification-training\/#webpage"},"isPartOf":{"@id":"https:\/\/develop.co.id\/training\/motor-current-measurement-and-protection-circuit-verification-training\/#webpage"},"articleSection":"Industrial Engineering, Instrument Engineering, Instrument Engineering"},{"@type":"BreadcrumbList","@id":"https:\/\/develop.co.id\/training\/motor-current-measurement-and-protection-circuit-verification-training\/#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/develop.co.id\/training\/#listItem","position":1,"name":"Home","item":"https:\/\/develop.co.id\/training\/","nextItem":{"@type":"ListItem","@id":"https:\/\/develop.co.id\/training\/category\/engineering-technical\/#listItem","name":"Engineering &amp; Technical"}},{"@type":"ListItem","@id":"https:\/\/develop.co.id\/training\/category\/engineering-technical\/#listItem","position":2,"name":"Engineering &amp; Technical","item":"https:\/\/develop.co.id\/training\/category\/engineering-technical\/","nextItem":{"@type":"ListItem","@id":"https:\/\/develop.co.id\/training\/category\/engineering-technical\/industrial-engineering\/#listItem","name":"Industrial Engineering"},"previousItem":{"@type":"ListItem","@id":"https:\/\/develop.co.id\/training\/#listItem","name":"Home"}},{"@type":"ListItem","@id":"https:\/\/develop.co.id\/training\/category\/engineering-technical\/industrial-engineering\/#listItem","position":3,"name":"Industrial Engineering","item":"https:\/\/develop.co.id\/training\/category\/engineering-technical\/industrial-engineering\/","nextItem":{"@type":"ListItem","@id":"https:\/\/develop.co.id\/training\/motor-current-measurement-and-protection-circuit-verification-training\/#listItem","name":"Motor Current Measurement and Protection Circuit Verification Training"},"previousItem":{"@type":"ListItem","@id":"https:\/\/develop.co.id\/training\/category\/engineering-technical\/#listItem","name":"Engineering &amp; Technical"}},{"@type":"ListItem","@id":"https:\/\/develop.co.id\/training\/motor-current-measurement-and-protection-circuit-verification-training\/#listItem","position":4,"name":"Motor Current Measurement and Protection Circuit Verification Training","previousItem":{"@type":"ListItem","@id":"https:\/\/develop.co.id\/training\/category\/engineering-technical\/industrial-engineering\/#listItem","name":"Industrial Engineering"}}]},{"@type":"Organization","@id":"https:\/\/develop.co.id\/training\/#organization","name":"DEVELOP","description":"Oil Gas,Petrochemical, Power Plant,Mining&Industrial Training Specialist","url":"https:\/\/develop.co.id\/training\/","telephone":"+628159147070","logo":{"@type":"ImageObject","url":"https:\/\/develop.co.id\/training\/wp-content\/uploads\/2026\/11\/develop-co-id-32-light-blue-300px.jpg","@id":"https:\/\/develop.co.id\/training\/motor-current-measurement-and-protection-circuit-verification-training\/#organizationLogo","width":300,"height":300},"image":{"@id":"https:\/\/develop.co.id\/training\/motor-current-measurement-and-protection-circuit-verification-training\/#organizationLogo"},"sameAs":["https:\/\/www.facebook.com\/sertifikasikerja","https:\/\/x.com\/oilgascourse","https:\/\/www.instagram.com\/developtrainingofficial","https:\/\/tiktok.com\/@develop.course","https:\/\/www.linkedin.com\/company\/develop-course"]},{"@type":"Person","@id":"https:\/\/develop.co.id\/training\/author\/developtraining\/#author","url":"https:\/\/develop.co.id\/training\/author\/developtraining\/","image":{"@type":"ImageObject","@id":"https:\/\/develop.co.id\/training\/motor-current-measurement-and-protection-circuit-verification-training\/#authorImage","url":"https:\/\/secure.gravatar.com\/avatar\/6b88ccabac9c627e76fb131519cdc3ef0e725eb1ff178c0eaa169a92fc8becc5?s=96&d=mm&r=g","width":96,"height":96}},{"@type":"WebPage","@id":"https:\/\/develop.co.id\/training\/motor-current-measurement-and-protection-circuit-verification-training\/#webpage","url":"https:\/\/develop.co.id\/training\/motor-current-measurement-and-protection-circuit-verification-training\/","name":"Motor Current Measurement and Protection Circuit Verification Training - DEVELOP","description":"Tingkatkan kemampuan profesional dalam pengukuran arus motor dan verifikasi proteksi untuk menemukan ketidakseimbangan, memeriksa CT, serta memastikan fungsi trip.","inLanguage":"en-US","isPartOf":{"@id":"https:\/\/develop.co.id\/training\/#website"},"breadcrumb":{"@id":"https:\/\/develop.co.id\/training\/motor-current-measurement-and-protection-circuit-verification-training\/#breadcrumblist"},"author":{"@id":"https:\/\/develop.co.id\/training\/author\/developtraining\/#author"},"creator":{"@id":"https:\/\/develop.co.id\/training\/author\/developtraining\/#author"},"image":{"@type":"ImageObject","url":"https:\/\/develop.co.id\/training\/wp-content\/uploads\/2026\/09\/motor-current-measurement-and-protection-circuit-verification-training_10760_2de0b.png","@id":"https:\/\/develop.co.id\/training\/motor-current-measurement-and-protection-circuit-verification-training\/#mainImage","width":800,"height":600},"primaryImageOfPage":{"@id":"https:\/\/develop.co.id\/training\/motor-current-measurement-and-protection-circuit-verification-training\/#mainImage"},"datePublished":"2026-08-30T15:28:33+00:00","dateModified":"2026-09-11T05:40:04+00:00"},{"@type":"WebSite","@id":"https:\/\/develop.co.id\/training\/#website","url":"https:\/\/develop.co.id\/training\/","name":"DEVELOP","description":"Oil Gas,Petrochemical, Power Plant,Mining&Industrial Training Specialist","inLanguage":"en-US","publisher":{"@id":"https:\/\/develop.co.id\/training\/#organization"}}]},"og:locale":"en_US","og:site_name":"DEVELOP - Oil Gas,Petrochemical, Power Plant,Mining&amp;Industrial Training Specialist","og:type":"article","og:title":"Motor Current Measurement and Protection Circuit Verification Training - DEVELOP","og:description":"Tingkatkan kemampuan profesional dalam pengukuran arus motor dan verifikasi proteksi untuk menemukan ketidakseimbangan, memeriksa CT, serta memastikan fungsi trip.","og:url":"https:\/\/develop.co.id\/training\/motor-current-measurement-and-protection-circuit-verification-training\/","og:image":"https:\/\/develop.co.id\/training\/wp-content\/uploads\/2026\/11\/develop-co-id-32-light-blue-300px.jpg","og:image:secure_url":"https:\/\/develop.co.id\/training\/wp-content\/uploads\/2026\/11\/develop-co-id-32-light-blue-300px.jpg","og:image:width":300,"og:image:height":300,"article:published_time":"2026-08-30T15:28:33+00:00","article:modified_time":"2026-09-11T05:40:04+00:00","article:publisher":"https:\/\/www.facebook.com\/sertifikasikerja","twitter:card":"summary_large_image","twitter:site":"@oilgascourse","twitter:title":"Motor Current Measurement and Protection Circuit Verification Training - DEVELOP","twitter:description":"Tingkatkan kemampuan profesional dalam pengukuran arus motor dan verifikasi proteksi untuk menemukan ketidakseimbangan, memeriksa CT, serta memastikan fungsi trip.","twitter:creator":"@oilgascourse","twitter:image":"https:\/\/develop.co.id\/training\/wp-content\/uploads\/2026\/11\/develop-co-id-32-light-blue-300px.jpg"},"aioseo_meta_data":{"post_id":"10760","title":null,"description":null,"keywords":null,"keyphrases":{"focus":[],"additional":[]},"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_custom_url":null,"og_image_custom_fields":null,"og_image_url":null,"og_image_width":null,"og_image_height":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":true,"twitter_card":"default","twitter_image_type":"default","twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_image_url":null,"twitter_title":null,"twitter_description":null,"schema_type":"default","schema_type_options":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"","isEnabled":true},"graphs":[]},"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"limit_modified_date":false,"ai":null,"breadcrumb_settings":null,"seo_analyzer_scan_date":null,"created":"2026-09-11 05:39:54","updated":"2026-09-11 08:30:58","focus_keyword":null,"additional_keywords":null,"truseo_locale":null},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/develop.co.id\/training\/\" title=\"Home\">Home<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/develop.co.id\/training\/category\/engineering-technical\/\" title=\"Engineering &amp; Technical\">Engineering &amp; Technical<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/develop.co.id\/training\/category\/engineering-technical\/industrial-engineering\/\" title=\"Industrial Engineering\">Industrial Engineering<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\tMotor Current Measurement and Protection Circuit Verification Training\n\t\t<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"Home","link":"https:\/\/develop.co.id\/training\/"},{"label":"Engineering &amp; Technical","link":"https:\/\/develop.co.id\/training\/category\/engineering-technical\/"},{"label":"Industrial Engineering","link":"https:\/\/develop.co.id\/training\/category\/engineering-technical\/industrial-engineering\/"},{"label":"Motor Current Measurement and Protection Circuit Verification Training","link":"https:\/\/develop.co.id\/training\/motor-current-measurement-and-protection-circuit-verification-training\/"}],"_links":{"self":[{"href":"https:\/\/develop.co.id\/training\/wp-json\/wp\/v2\/posts\/10760","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/develop.co.id\/training\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/develop.co.id\/training\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/develop.co.id\/training\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/develop.co.id\/training\/wp-json\/wp\/v2\/comments?post=10760"}],"version-history":[{"count":0,"href":"https:\/\/develop.co.id\/training\/wp-json\/wp\/v2\/posts\/10760\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/develop.co.id\/training\/wp-json\/wp\/v2\/media\/11333"}],"wp:attachment":[{"href":"https:\/\/develop.co.id\/training\/wp-json\/wp\/v2\/media?parent=10760"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/develop.co.id\/training\/wp-json\/wp\/v2\/categories?post=10760"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/develop.co.id\/training\/wp-json\/wp\/v2\/tags?post=10760"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}