{"id":10345,"date":"2017-11-14T10:30:03","date_gmt":"2017-11-14T10:30:03","guid":{"rendered":"https:\/\/develop.co.id\/training\/protection-relay-coordination-principles-training\/"},"modified":"2026-08-29T01:10:13","modified_gmt":"2026-08-29T01:10:13","slug":"protection-relay-coordination-principles-training","status":"publish","type":"post","link":"https:\/\/develop.co.id\/training\/protection-relay-coordination-principles-training\/","title":{"rendered":"Protection Relay Coordination Principles Training"},"content":{"rendered":"<p>DEVELOP Training Center menyelenggarakan Kelas Protection Relay Coordination Principles Training yang sangat berguna untuk mendapatkan pengetahuan tentang koordinasi relay proteksi, perhitungan arus gangguan, nilai pickup, karakteristik waktu-arus, grading relay, selektivitas, serta penyusunan pengaturan proteksi sistem tenaga.. <br \/><\/br> Pelatihan dilakukan dengan cara menyampaikan materi dan melakukan diskusi interaktif di kelas. Peserta pelatihan didorong untuk berperan aktif dalam memahami materi yang diberikan oleh instruktur. <br \/><\/br> <center> <img fetchpriority=\"high\" decoding=\"async\" class=\"aligncenter size-full wp-image-6218\" src=\"https:\/\/develop.co.id\/wp-content\/uploads\/2024\/08\/phkt-jogja4-wm-400-DEVELOP.jpg\" alt=\"Protection Relay Coordination Principles Training\" width=\"300\" height=\"300\"><figcaption> Protection Relay Coordination Principles Training <\/figcaption><\/center> <br \/><\/br> DEVELOP mengimplementasikan Syllabus Kelas Protection Relay Coordination Principles Training dengan tahap pembelajaran berkualitas sebagai berikut:<\/p>\n<blockquote><p><b>Sesi 1-2<\/b><\/p>\n<ul>\n<li>Protection relay coordination concepts and objectives<\/li>\n<li>Electrical network topology and protection zones<\/li>\n<li>Fault current calculation for coordination studies<\/li>\n<li>Relay pickup current and operating thresholds<\/li>\n<li>Time-current characteristic curves and relay grading<\/li>\n<li>Inverse time and definite time relay characteristics<\/li>\n<li>Overcurrent relay coordination for radial feeders<\/li>\n<li>Earth fault relay coordination requirements<\/li>\n<li>Circuit breaker operating time and interrupting characteristics<\/li>\n<li>Current transformer ratio selection for relay coordination<\/li>\n<li>Protection grading margins and selectivity assessment<\/li>\n<li>Case Study<\/li>\n<\/ul>\n<p><b>Sesi 3-4<\/b><\/p>\n<ul>\n<li>Feeder relay coordination and upstream-downstream grading<\/li>\n<li>Transformer overcurrent protection coordination<\/li>\n<li>Motor protection relay coordination<\/li>\n<li>Generator feeder protection coordination<\/li>\n<li>Busbar fault protection and backup grading<\/li>\n<li>Fuse and relay coordination arrangements<\/li>\n<li>Relay setting calculations and coordination worksheets<\/li>\n<li>Time-current curve plotting and comparison<\/li>\n<li>Coordination assessment for multiple operating conditions<\/li>\n<li>Protection miscoordination causes and corrective measures<\/li>\n<li>Coordination study reporting and setting documentation<\/li>\n<li>Relay coordination verification and commissioning preparation<\/li>\n<li>Case Study<\/li>\n<\/ul>\n<\/blockquote>\n<p><\/br> Sejalan dengan teori yang disampaikan, sebanyak mungkin akan disertakan contoh-contoh studi kasus yang relevan dengan kondisi aktual di industri. Peserta juga diberikan kesempatan untuk mengajukan pertanyaan dan mendiskusikan topik-topik yang dibahas. <br \/><\/br> <center> <img decoding=\"async\" class=\"aligncenter size-full wp-image-23817\" src=\"https:\/\/develop.co.id\/wp-content\/uploads\/2025\/07\/DV-TESTIMONIAL-008.jpg\" alt=\"Protection Relay Coordination Principles Training\" width=\"400\" height=\"400\"><figcaption> Protection Relay Coordination Principles Training <\/figcaption><\/center> <br \/><\/br> Materi Training dirancang khusus oleh para praktisi dan tenaga ahli yang kompeten serta telah berpengalaman sesuai dengan experience dan solid knowledge  mereka. Anda akan mendapat sharing ilmu langsung dari para praktisi yang berpengalaman bertahun-tahun. <br \/><\/br> Selama training, instruktur kami akan menggunakan kombinasi teori serta praktek langsung dengan studi kasus telah dipersiapkan yang menyerupai Proyek nyata. <br \/><\/br> \n<div class=\"wpcf7 no-js\" id=\"wpcf7-f4427-o1\" lang=\"en-US\" dir=\"ltr\" data-wpcf7-id=\"4427\">\n<div class=\"screen-reader-response\"><p role=\"status\" aria-live=\"polite\" aria-atomic=\"true\"><\/p> <ul><\/ul><\/div>\n<form action=\"\/training\/wp-json\/wp\/v2\/posts\/10345#wpcf7-f4427-o1\" method=\"post\" class=\"wpcf7-form init\" aria-label=\"Contact form\" novalidate=\"novalidate\" data-status=\"init\">\n<fieldset class=\"hidden-fields-container\"><input type=\"hidden\" name=\"_wpcf7\" value=\"4427\" \/><input type=\"hidden\" name=\"_wpcf7_version\" value=\"6.2.5\" \/><input type=\"hidden\" name=\"_wpcf7_locale\" value=\"en_US\" \/><input type=\"hidden\" name=\"_wpcf7_unit_tag\" value=\"wpcf7-f4427-o1\" \/><input type=\"hidden\" name=\"_wpcf7_container_post\" value=\"0\" \/><input type=\"hidden\" name=\"_wpcf7_posted_data_hash\" value=\"\" \/>\n<\/fieldset>\n<blockquote>\n\t<p><b>QUICK REGISTRATION &#10004;<\/b>\n\t<\/p>\n<\/blockquote>\n<div class=\"c-input-group\">\n\t<p><span class=\"wpcf7-form-control-wrap\" data-name=\"your-name\"><input size=\"40\" maxlength=\"400\" class=\"wpcf7-form-control wpcf7-text wpcf7-validates-as-required\" aria-required=\"true\" aria-invalid=\"false\" placeholder=\"Full name\" value=\"\" type=\"text\" name=\"your-name\" \/><\/span><br \/>\n<span class=\"wpcf7-form-control-wrap\" data-name=\"your-email\"><input size=\"40\" maxlength=\"400\" class=\"wpcf7-form-control wpcf7-email wpcf7-validates-as-required wpcf7-text wpcf7-validates-as-email\" aria-required=\"true\" aria-invalid=\"false\" placeholder=\"Email\" value=\"\" type=\"email\" name=\"your-email\" \/><\/span><br \/>\n<span class=\"wpcf7-form-control-wrap\" data-name=\"tel-428\"><input size=\"40\" maxlength=\"400\" class=\"wpcf7-form-control wpcf7-tel wpcf7-validates-as-required wpcf7-text wpcf7-validates-as-tel\" aria-required=\"true\" aria-invalid=\"false\" placeholder=\"Phone\" value=\"\" type=\"tel\" name=\"tel-428\" \/><\/span>\n\t<\/p>\n\t<p><span class=\"wpcf7-form-control-wrap\" data-name=\"your-message\"><textarea cols=\"10\" rows=\"10\" maxlength=\"2000\" class=\"wpcf7-form-control wpcf7-textarea\" aria-invalid=\"false\" placeholder=\"Special message\" name=\"your-message\"><\/textarea><\/span>\n\t<\/p>\n\t<p><span id=\"wpcf7-6b01277505890-wrapper\" class=\"wpcf7-form-control-wrap cf7apps-honeypot-wrap honeypot-469-wrap\" data-cf7apps-honeypot=\"honeypot-469\" style=\"position:absolute;width:1px;height:1px;padding:0;margin:-1px;overflow:hidden;clip:rect(0,0,0,0);white-space:nowrap;border:0;\"><input type=\"hidden\" name=\"honeypot-469-random-hash\" value=\"20261121\"><input type=\"hidden\" name=\"honeypot-469-time-token\" value=\"MTc5NTIzNzc0OQ==.5d12788cca2939bb276030cb8fed727bb4120e2488e5a05260e6c07609e57ea6\"><label\n\t\t    for=\"wpcf7-6b01277505890-field\"\n\t\t    class=\"hp-message\"\n        >Please leave this field empty.<\/label><input\n\t    id=\"wpcf7-6b01277505890-field\"\n\t    \n\t    class=\"wpcf7-form-control wpcf7-text\"\n\t    type=\"text\"\n\t    name=\"ghyw3azccfl5\"\n\t    value=\"\"\n\t    autocomplete=\"new-password\"\n\t    tabindex=\"1000\"\n\t    data-cf7apps-tabindex=\"1000\"\n    \/><\/span><br \/>\n<input class=\"wpcf7-form-control wpcf7-submit has-spinner\" type=\"submit\" value=\"REGISTER NOW\" \/>\n\t<\/p>\n<\/div><div class=\"wpcf7-response-output\" aria-hidden=\"true\"><\/div>\n<\/form>\n<\/div>\n<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Pelajari koordinasi relay proteksi untuk meningkatkan kemampuan menentukan setting, grading, selektivitas, dan verifikasi sistem proteksi tenaga listrik.<\/p>\n","protected":false},"author":1,"featured_media":10503,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_monsterinsights_skip_tracking":false,"footnotes":""},"categories":[38,50],"tags":[5413,11294,11291,2499,11293,11289,11287,11295,11288,11290,11292],"class_list":["post-10345","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-instrument-engineering","category-instrument-maintenance-operation","tag-electrical-protection-coordination","tag-fault-current-coordination-study","tag-feeder-relay-coordination","tag-instrument-engineering","tag-motor-protection-coordination","tag-overcurrent-relay-settings","tag-protection-relay-coordination-course","tag-protective-relay-engineering","tag-relay-grading-study-training","tag-time-current-curve-training","tag-transformer-relay-grading"],"aioseo_notices":[],"aioseo_head":"\n\t\t<!-- All in One SEO 5.0.5.1 - aioseo.com -->\n\t<meta name=\"description\" content=\"Pelajari koordinasi relay proteksi untuk meningkatkan kemampuan menentukan setting, grading, selektivitas, dan verifikasi sistem proteksi tenaga listrik.\" \/>\n\t<meta name=\"robots\" content=\"max-image-preview:large\" \/>\n\t<link rel=\"canonical\" href=\"https:\/\/develop.co.id\/training\/protection-relay-coordination-principles-training\/\" \/>\n\t\t<meta name=\"generator\" content=\"All in One SEO (AIOSEO) 5.0.5.1\" \/>\n\t\t<meta property=\"og:locale\" content=\"en_US\" \/>\n\t\t<meta property=\"og:site_name\" content=\"DEVELOP - Oil Gas,Petrochemical, Power Plant,Mining&amp;Industrial Training Specialist\" \/>\n\t\t<meta property=\"og:type\" content=\"article\" \/>\n\t\t<meta property=\"og:title\" content=\"Protection Relay Coordination Principles Training - DEVELOP\" \/>\n\t\t<meta property=\"og:description\" content=\"Pelajari koordinasi relay proteksi untuk meningkatkan kemampuan menentukan setting, grading, selektivitas, dan verifikasi sistem proteksi tenaga listrik.\" \/>\n\t\t<meta property=\"og:url\" content=\"https:\/\/develop.co.id\/training\/protection-relay-coordination-principles-training\/\" \/>\n\t\t<meta property=\"og:image\" content=\"https:\/\/develop.co.id\/training\/wp-content\/uploads\/2026\/07\/DEVELOP-Logo-ls4-300x150-1.png\" \/>\n\t\t<meta property=\"og:image:secure_url\" content=\"https:\/\/develop.co.id\/training\/wp-content\/uploads\/2026\/07\/DEVELOP-Logo-ls4-300x150-1.png\" \/>\n\t\t<meta property=\"article:published_time\" content=\"2017-11-14T10:30:03+00:00\" \/>\n\t\t<meta property=\"article:modified_time\" content=\"2026-08-29T01:10:13+00:00\" \/>\n\t\t<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n\t\t<meta name=\"twitter:title\" content=\"Protection Relay Coordination Principles Training - DEVELOP\" \/>\n\t\t<meta name=\"twitter:description\" content=\"Pelajari koordinasi relay proteksi untuk meningkatkan kemampuan menentukan setting, grading, selektivitas, dan verifikasi sistem proteksi tenaga listrik.\" \/>\n\t\t<meta name=\"twitter:image\" content=\"https:\/\/develop.co.id\/training\/wp-content\/uploads\/2026\/07\/DEVELOP-Logo-ls4-300x150-1.png\" \/>\n\t\t<script type=\"application\/ld+json\" class=\"aioseo-schema\">\n\t\t\t{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"BlogPosting\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/protection-relay-coordination-principles-training\\\/#blogposting\",\"name\":\"Protection Relay Coordination Principles Training - DEVELOP\",\"headline\":\"Protection Relay Coordination Principles Training\",\"author\":{\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/author\\\/developtraining\\\/#author\"},\"publisher\":{\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/#organization\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/develop.co.id\\\/training\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/protection-relay-coordination-principles-training_10345_8cdf3.png\",\"width\":800,\"height\":600},\"datePublished\":\"2017-11-14T10:30:03+00:00\",\"dateModified\":\"2026-08-29T01:10:13+00:00\",\"inLanguage\":\"en-US\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/protection-relay-coordination-principles-training\\\/#webpage\"},\"isPartOf\":{\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/protection-relay-coordination-principles-training\\\/#webpage\"},\"articleSection\":\"Instrument Engineering, Instrument Maintenance &amp; Operation, electrical protection coordination, fault current coordination study, feeder relay coordination, Instrument Engineering, motor protection coordination, overcurrent relay settings, protection relay coordination course, protective relay engineering, relay grading study training, time current curve training, transformer relay grading\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/protection-relay-coordination-principles-training\\\/#breadcrumblist\",\"itemListElement\":[{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/#listItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/develop.co.id\\\/training\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/category\\\/engineering-technical\\\/#listItem\",\"name\":\"Engineering &amp; Technical\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/category\\\/engineering-technical\\\/#listItem\",\"position\":2,\"name\":\"Engineering &amp; Technical\",\"item\":\"https:\\\/\\\/develop.co.id\\\/training\\\/category\\\/engineering-technical\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/category\\\/engineering-technical\\\/instrument-engineering\\\/#listItem\",\"name\":\"Instrument Engineering\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/#listItem\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/category\\\/engineering-technical\\\/instrument-engineering\\\/#listItem\",\"position\":3,\"name\":\"Instrument Engineering\",\"item\":\"https:\\\/\\\/develop.co.id\\\/training\\\/category\\\/engineering-technical\\\/instrument-engineering\\\/\",\"nextItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/protection-relay-coordination-principles-training\\\/#listItem\",\"name\":\"Protection Relay Coordination Principles Training\"},\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/category\\\/engineering-technical\\\/#listItem\",\"name\":\"Engineering &amp; Technical\"}},{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/protection-relay-coordination-principles-training\\\/#listItem\",\"position\":4,\"name\":\"Protection Relay Coordination Principles Training\",\"previousItem\":{\"@type\":\"ListItem\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/category\\\/engineering-technical\\\/instrument-engineering\\\/#listItem\",\"name\":\"Instrument Engineering\"}}]},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/#organization\",\"name\":\"DEVELOP\",\"description\":\"Oil Gas,Petrochemical, Power Plant,Mining&Industrial Training Specialist\",\"url\":\"https:\\\/\\\/develop.co.id\\\/training\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/develop.co.id\\\/training\\\/wp-content\\\/uploads\\\/2026\\\/07\\\/DEVELOP-Logo-ls4-300x150-1.png\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/protection-relay-coordination-principles-training\\\/#organizationLogo\",\"width\":300,\"height\":150},\"image\":{\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/protection-relay-coordination-principles-training\\\/#organizationLogo\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/author\\\/developtraining\\\/#author\",\"url\":\"https:\\\/\\\/develop.co.id\\\/training\\\/author\\\/developtraining\\\/\",\"image\":{\"@type\":\"ImageObject\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/protection-relay-coordination-principles-training\\\/#authorImage\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/6b88ccabac9c627e76fb131519cdc3ef0e725eb1ff178c0eaa169a92fc8becc5?s=96&d=mm&r=g\",\"width\":96,\"height\":96}},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/protection-relay-coordination-principles-training\\\/#webpage\",\"url\":\"https:\\\/\\\/develop.co.id\\\/training\\\/protection-relay-coordination-principles-training\\\/\",\"name\":\"Protection Relay Coordination Principles Training - DEVELOP\",\"description\":\"Pelajari koordinasi relay proteksi untuk meningkatkan kemampuan menentukan setting, grading, selektivitas, dan verifikasi sistem proteksi tenaga listrik.\",\"inLanguage\":\"en-US\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/#website\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/protection-relay-coordination-principles-training\\\/#breadcrumblist\"},\"author\":{\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/author\\\/developtraining\\\/#author\"},\"creator\":{\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/author\\\/developtraining\\\/#author\"},\"image\":{\"@type\":\"ImageObject\",\"url\":\"https:\\\/\\\/develop.co.id\\\/training\\\/wp-content\\\/uploads\\\/2026\\\/08\\\/protection-relay-coordination-principles-training_10345_8cdf3.png\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/protection-relay-coordination-principles-training\\\/#mainImage\",\"width\":800,\"height\":600},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/protection-relay-coordination-principles-training\\\/#mainImage\"},\"datePublished\":\"2017-11-14T10:30:03+00:00\",\"dateModified\":\"2026-08-29T01:10:13+00:00\"},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/#website\",\"url\":\"https:\\\/\\\/develop.co.id\\\/training\\\/\",\"name\":\"DEVELOP\",\"description\":\"Oil Gas,Petrochemical, Power Plant,Mining&Industrial Training Specialist\",\"inLanguage\":\"en-US\",\"publisher\":{\"@id\":\"https:\\\/\\\/develop.co.id\\\/training\\\/#organization\"}}]}\n\t\t<\/script>\n\t\t<!-- All in One SEO -->\n\n","aioseo_head_json":{"title":"Protection Relay Coordination Principles Training - DEVELOP","description":"Pelajari koordinasi relay proteksi untuk meningkatkan kemampuan menentukan setting, grading, selektivitas, dan verifikasi sistem proteksi tenaga listrik.","canonical_url":"https:\/\/develop.co.id\/training\/protection-relay-coordination-principles-training\/","robots":"max-image-preview:large","keywords":"","webmasterTools":{"miscellaneous":""},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"BlogPosting","@id":"https:\/\/develop.co.id\/training\/protection-relay-coordination-principles-training\/#blogposting","name":"Protection Relay Coordination Principles Training - DEVELOP","headline":"Protection Relay Coordination Principles Training","author":{"@id":"https:\/\/develop.co.id\/training\/author\/developtraining\/#author"},"publisher":{"@id":"https:\/\/develop.co.id\/training\/#organization"},"image":{"@type":"ImageObject","url":"https:\/\/develop.co.id\/training\/wp-content\/uploads\/2026\/08\/protection-relay-coordination-principles-training_10345_8cdf3.png","width":800,"height":600},"datePublished":"2017-11-14T10:30:03+00:00","dateModified":"2026-08-29T01:10:13+00:00","inLanguage":"en-US","mainEntityOfPage":{"@id":"https:\/\/develop.co.id\/training\/protection-relay-coordination-principles-training\/#webpage"},"isPartOf":{"@id":"https:\/\/develop.co.id\/training\/protection-relay-coordination-principles-training\/#webpage"},"articleSection":"Instrument Engineering, Instrument Maintenance &amp; Operation, electrical protection coordination, fault current coordination study, feeder relay coordination, Instrument Engineering, motor protection coordination, overcurrent relay settings, protection relay coordination course, protective relay engineering, relay grading study training, time current curve training, transformer relay grading"},{"@type":"BreadcrumbList","@id":"https:\/\/develop.co.id\/training\/protection-relay-coordination-principles-training\/#breadcrumblist","itemListElement":[{"@type":"ListItem","@id":"https:\/\/develop.co.id\/training\/#listItem","position":1,"name":"Home","item":"https:\/\/develop.co.id\/training\/","nextItem":{"@type":"ListItem","@id":"https:\/\/develop.co.id\/training\/category\/engineering-technical\/#listItem","name":"Engineering &amp; Technical"}},{"@type":"ListItem","@id":"https:\/\/develop.co.id\/training\/category\/engineering-technical\/#listItem","position":2,"name":"Engineering &amp; Technical","item":"https:\/\/develop.co.id\/training\/category\/engineering-technical\/","nextItem":{"@type":"ListItem","@id":"https:\/\/develop.co.id\/training\/category\/engineering-technical\/instrument-engineering\/#listItem","name":"Instrument Engineering"},"previousItem":{"@type":"ListItem","@id":"https:\/\/develop.co.id\/training\/#listItem","name":"Home"}},{"@type":"ListItem","@id":"https:\/\/develop.co.id\/training\/category\/engineering-technical\/instrument-engineering\/#listItem","position":3,"name":"Instrument Engineering","item":"https:\/\/develop.co.id\/training\/category\/engineering-technical\/instrument-engineering\/","nextItem":{"@type":"ListItem","@id":"https:\/\/develop.co.id\/training\/protection-relay-coordination-principles-training\/#listItem","name":"Protection Relay Coordination Principles Training"},"previousItem":{"@type":"ListItem","@id":"https:\/\/develop.co.id\/training\/category\/engineering-technical\/#listItem","name":"Engineering &amp; Technical"}},{"@type":"ListItem","@id":"https:\/\/develop.co.id\/training\/protection-relay-coordination-principles-training\/#listItem","position":4,"name":"Protection Relay Coordination Principles Training","previousItem":{"@type":"ListItem","@id":"https:\/\/develop.co.id\/training\/category\/engineering-technical\/instrument-engineering\/#listItem","name":"Instrument Engineering"}}]},{"@type":"Organization","@id":"https:\/\/develop.co.id\/training\/#organization","name":"DEVELOP","description":"Oil Gas,Petrochemical, Power Plant,Mining&Industrial Training Specialist","url":"https:\/\/develop.co.id\/training\/","logo":{"@type":"ImageObject","url":"https:\/\/develop.co.id\/training\/wp-content\/uploads\/2026\/07\/DEVELOP-Logo-ls4-300x150-1.png","@id":"https:\/\/develop.co.id\/training\/protection-relay-coordination-principles-training\/#organizationLogo","width":300,"height":150},"image":{"@id":"https:\/\/develop.co.id\/training\/protection-relay-coordination-principles-training\/#organizationLogo"}},{"@type":"Person","@id":"https:\/\/develop.co.id\/training\/author\/developtraining\/#author","url":"https:\/\/develop.co.id\/training\/author\/developtraining\/","image":{"@type":"ImageObject","@id":"https:\/\/develop.co.id\/training\/protection-relay-coordination-principles-training\/#authorImage","url":"https:\/\/secure.gravatar.com\/avatar\/6b88ccabac9c627e76fb131519cdc3ef0e725eb1ff178c0eaa169a92fc8becc5?s=96&d=mm&r=g","width":96,"height":96}},{"@type":"WebPage","@id":"https:\/\/develop.co.id\/training\/protection-relay-coordination-principles-training\/#webpage","url":"https:\/\/develop.co.id\/training\/protection-relay-coordination-principles-training\/","name":"Protection Relay Coordination Principles Training - DEVELOP","description":"Pelajari koordinasi relay proteksi untuk meningkatkan kemampuan menentukan setting, grading, selektivitas, dan verifikasi sistem proteksi tenaga listrik.","inLanguage":"en-US","isPartOf":{"@id":"https:\/\/develop.co.id\/training\/#website"},"breadcrumb":{"@id":"https:\/\/develop.co.id\/training\/protection-relay-coordination-principles-training\/#breadcrumblist"},"author":{"@id":"https:\/\/develop.co.id\/training\/author\/developtraining\/#author"},"creator":{"@id":"https:\/\/develop.co.id\/training\/author\/developtraining\/#author"},"image":{"@type":"ImageObject","url":"https:\/\/develop.co.id\/training\/wp-content\/uploads\/2026\/08\/protection-relay-coordination-principles-training_10345_8cdf3.png","@id":"https:\/\/develop.co.id\/training\/protection-relay-coordination-principles-training\/#mainImage","width":800,"height":600},"primaryImageOfPage":{"@id":"https:\/\/develop.co.id\/training\/protection-relay-coordination-principles-training\/#mainImage"},"datePublished":"2017-11-14T10:30:03+00:00","dateModified":"2026-08-29T01:10:13+00:00"},{"@type":"WebSite","@id":"https:\/\/develop.co.id\/training\/#website","url":"https:\/\/develop.co.id\/training\/","name":"DEVELOP","description":"Oil Gas,Petrochemical, Power Plant,Mining&Industrial Training Specialist","inLanguage":"en-US","publisher":{"@id":"https:\/\/develop.co.id\/training\/#organization"}}]},"og:locale":"en_US","og:site_name":"DEVELOP - Oil Gas,Petrochemical, Power Plant,Mining&amp;Industrial Training Specialist","og:type":"article","og:title":"Protection Relay Coordination Principles Training - DEVELOP","og:description":"Pelajari koordinasi relay proteksi untuk meningkatkan kemampuan menentukan setting, grading, selektivitas, dan verifikasi sistem proteksi tenaga listrik.","og:url":"https:\/\/develop.co.id\/training\/protection-relay-coordination-principles-training\/","og:image":"https:\/\/develop.co.id\/training\/wp-content\/uploads\/2026\/07\/DEVELOP-Logo-ls4-300x150-1.png","og:image:secure_url":"https:\/\/develop.co.id\/training\/wp-content\/uploads\/2026\/07\/DEVELOP-Logo-ls4-300x150-1.png","article:published_time":"2017-11-14T10:30:03+00:00","article:modified_time":"2026-08-29T01:10:13+00:00","twitter:card":"summary_large_image","twitter:title":"Protection Relay Coordination Principles Training - DEVELOP","twitter:description":"Pelajari koordinasi relay proteksi untuk meningkatkan kemampuan menentukan setting, grading, selektivitas, dan verifikasi sistem proteksi tenaga listrik.","twitter:image":"https:\/\/develop.co.id\/training\/wp-content\/uploads\/2026\/07\/DEVELOP-Logo-ls4-300x150-1.png"},"aioseo_meta_data":{"post_id":"10345","title":null,"description":null,"keywords":null,"keyphrases":{"focus":[],"additional":[]},"primary_term":null,"canonical_url":null,"og_title":null,"og_description":null,"og_object_type":"default","og_image_type":"default","og_image_custom_url":null,"og_image_custom_fields":null,"og_image_url":null,"og_image_width":null,"og_image_height":null,"og_video":null,"og_custom_url":null,"og_article_section":null,"og_article_tags":null,"twitter_use_og":true,"twitter_card":"default","twitter_image_type":"default","twitter_image_custom_url":null,"twitter_image_custom_fields":null,"twitter_image_url":null,"twitter_title":null,"twitter_description":null,"schema_type":"default","schema_type_options":null,"schema":{"blockGraphs":[],"customGraphs":[],"default":{"data":{"Article":[],"Course":[],"Dataset":[],"FAQPage":[],"Movie":[],"Person":[],"Product":[],"ProductReview":[],"Car":[],"Recipe":[],"Service":[],"SoftwareApplication":[],"WebPage":[]},"graphName":"","isEnabled":true},"graphs":[]},"pillar_content":false,"robots_default":true,"robots_noindex":false,"robots_noarchive":false,"robots_nosnippet":false,"robots_nofollow":false,"robots_noimageindex":false,"robots_noodp":false,"robots_notranslate":false,"robots_max_snippet":null,"robots_max_videopreview":null,"robots_max_imagepreview":"large","priority":null,"frequency":null,"local_seo":null,"limit_modified_date":false,"ai":null,"breadcrumb_settings":null,"seo_analyzer_scan_date":null,"created":"2026-08-29 01:09:55","updated":"2026-08-29 02:47:50","focus_keyword":null,"additional_keywords":null,"truseo_locale":null},"aioseo_breadcrumb":"<div class=\"aioseo-breadcrumbs\"><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/develop.co.id\/training\/\" title=\"Home\">Home<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/develop.co.id\/training\/category\/engineering-technical\/\" title=\"Engineering &amp; Technical\">Engineering &amp; Technical<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\t<a href=\"https:\/\/develop.co.id\/training\/category\/engineering-technical\/instrument-engineering\/\" title=\"Instrument Engineering\">Instrument Engineering<\/a>\n\t\t<\/span><span class=\"aioseo-breadcrumb-separator\">\u00bb<\/span><span class=\"aioseo-breadcrumb\">\n\t\t\tProtection Relay Coordination Principles Training\n\t\t<\/span><\/div>","aioseo_breadcrumb_json":[{"label":"Home","link":"https:\/\/develop.co.id\/training\/"},{"label":"Engineering &amp; Technical","link":"https:\/\/develop.co.id\/training\/category\/engineering-technical\/"},{"label":"Instrument Engineering","link":"https:\/\/develop.co.id\/training\/category\/engineering-technical\/instrument-engineering\/"},{"label":"Protection Relay Coordination Principles Training","link":"https:\/\/develop.co.id\/training\/protection-relay-coordination-principles-training\/"}],"_links":{"self":[{"href":"https:\/\/develop.co.id\/training\/wp-json\/wp\/v2\/posts\/10345","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/develop.co.id\/training\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/develop.co.id\/training\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/develop.co.id\/training\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/develop.co.id\/training\/wp-json\/wp\/v2\/comments?post=10345"}],"version-history":[{"count":0,"href":"https:\/\/develop.co.id\/training\/wp-json\/wp\/v2\/posts\/10345\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/develop.co.id\/training\/wp-json\/wp\/v2\/media\/10503"}],"wp:attachment":[{"href":"https:\/\/develop.co.id\/training\/wp-json\/wp\/v2\/media?parent=10345"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/develop.co.id\/training\/wp-json\/wp\/v2\/categories?post=10345"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/develop.co.id\/training\/wp-json\/wp\/v2\/tags?post=10345"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}